Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

Outdoor Telephone Cables,Indoor Telephone Cables,Indoor/Outdoor Telephone Cables,Special Telephone Cables,CW 1171,CW 1326,CW 1326/1179,IEC 60708,DIN VDE 0816,GR-421,ICEA S-85-625,ICEA S-84-608,CW 1224,CW 1236,CW 1128,CW 1128/1179,PE-89,PE-7,CW 1166, CW 208, CW 1247,CW 1320A,CW 1406, CW 1411, CW 1417 ,CW 1378,IEC 60189-1,CW 1109, CW 1257,CW 1423,CW 1293,CW 1308,CW 1600,DIN VDE 0815,DIN VDE 0815/DIN 57815,Category 3 UTP/FTP Cables,ADSL Connecting Cables,XDSL Connecting Cables,ISDN Primary Access Air Core Cables,PE Insulated ISDN Basic Access Air Core Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ADDISON<br />

PE Insulated Category 3 UTP/FTP Cables<br />

APPLICATION<br />

The <strong>cable</strong>s are designed for medium frequency data or <strong>telephone</strong> systems, suitable for<br />

indoor or outdoor insulations.<br />

STANDARDS<br />

• TIA/EIA-568B<br />

• IEC 61156-4<br />

• UL-444<br />

• ANSI/ICEA S-80-576<br />

CONSTRUCTION<br />

• Conductors: Solid annealed bare copper sized 0.5mm (24 AWG) as per ASTM-B3/class 1 of IEC 60228.<br />

• Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708.<br />

• Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.<br />

• Cable Core Assembly: The 50-pair <strong>cable</strong> is composed of 4 units having 12 or 13 pairs each. All other <strong>cable</strong>s are<br />

composed of 25-pair units. Units are identified by colour coded binders.<br />

• Core Wrapping: Non-hygroscopic dielectric tape fully enclosing the core with an overlap.<br />

• Screen (optional): An optional Aluminium/Polyester tape placed in contact with solid copper drain wire may be provided<br />

as an option.<br />

• Sheath: PVC or LSZH.<br />

• Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.<br />

ELECTRICAL PROPERTIES<br />

Nominal Conductor Diameter mm 0.5<br />

Maximum DC Resistance Ω/100m 9.38<br />

Maximum Resistance Unbalance % 5<br />

Maximum Capacitance Unbalance pair-to-ground @1KHz pF/100m 330<br />

Minimum Worst Pair Structural Return Loss (SRL):<br />

Up to 10 MHz dB 12<br />

Between 10 and 16 MHz dB 10<br />

Impedance @1-16 MHz Ω 85 - 115<br />

Maximum Attenuation at 20°C<br />

@64KHz dB/100m 0.9<br />

@256KHz dB/100m 1.3<br />

126 Caledonian Telephone Cables www.addison-<strong>cable</strong>s.com www.<strong>caledonian</strong>-<strong>cable</strong>s.co.uk