Pub #105174revA<br />

<strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong><br />

461091 - (Flat mount)<br />

465026 - (DIN rail mount)<br />

process networking solutions<br />

The <strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong> extends the <strong>AS</strong>-<strong>Interface</strong> network by an<br />

additional 100 meters. The <strong>Repeater</strong> requires no configuration and has<br />

no address on the bus. An additional <strong>AS</strong>-<strong>Interface</strong> power supply is<br />

required for the additional 100 meters of <strong>AS</strong>-<strong>Interface</strong> network.<br />

Features<br />

- LED indication for bus segments power status<br />

- <strong>Repeater</strong> is unidirectional (Network segments can be landed on either side<br />

- Redundant termination points for convenient wiring of the additional power supply<br />

- Direct mount or DIN rail mount<br />

(See reverse for specifications and detailed wiring instructions)<br />

<strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong> <strong>Specifications</strong> <strong>Module</strong> <strong>Dimensions</strong><br />

Ø 3mm<br />

40mm<br />

75mm<br />

67mm<br />

13mm<br />

8mm<br />

35mm<br />

26mm<br />

<strong>StoneL</strong> Corporation<br />

One <strong>StoneL</strong> Dr<br />

26275 US Hwy 59<br />

Fergus Falls, MN 56537<br />

USA<br />

Approval Agency Controlled Document.<br />

No Changes Authorized Without Prior Agency Approval<br />

© 2001 <strong>StoneL</strong> Corporation<br />

Telephone: 218.739.5774<br />

Toll Free: 800.843.7866<br />

Fax: 218.739.5776<br />

E-mail: sales@stonel.com<br />

Website: www.stonel.com


Operating Voltage<br />

Max Voltage<br />

Current Usage<br />

Pub #105174revA<br />

Page 2<br />

<strong>AS</strong>-<strong>Interface</strong> Cycle Time 0.15ms x (number of slaves + 1)<br />

LED Indication<br />

Bus Power On (both segments)<br />

Temp Range<br />

-40° to +80°C<br />

<strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong> <strong>Specifications</strong><br />

<strong>AS</strong>-<strong>Interface</strong> voltage<br />

31.6 VDC<br />

60mA (per segment), 120mA total<br />

<strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong> Wiring Diagram and Installation Notes<br />

<strong>AS</strong>I 1 +<br />

<strong>AS</strong>I 2 -<br />

1<br />

2<br />

<strong>AS</strong>I 1 -<br />

<strong>AS</strong>I 1 +<br />

<strong>AS</strong>I 1 -<br />

BUS<br />

ON<br />

BUS<br />

ON<br />

<strong>AS</strong>I 2 +<br />

<strong>AS</strong>I 2 -<br />

<strong>AS</strong>I 2 +<br />

1<br />

2<br />

3 GREEN LED’s<br />

100 meters max 100 meters max<br />

Master<br />

Power<br />

Supply<br />

Power<br />

Supply<br />

Segment 1 Segment 2<br />

<strong>Repeater</strong><br />

Field Device 1<br />

Field Device n<br />

Field Device n<br />

Field Device<br />

31/62<br />

1<br />

2<br />

3<br />

INSTALLATION NOTES:<br />

1. The <strong>AS</strong>-<strong>Interface</strong> <strong>Repeater</strong> is unidirectional. Segment 1 can be connected to either the <strong>AS</strong>I 1or <strong>AS</strong>I 2 side with<br />

Segment 2 being connected to the opposite side of Segment 1.<br />

2. Redundant terminal points on both <strong>AS</strong>I 1and <strong>AS</strong>I 2 sides for convenient wiring of the required <strong>AS</strong>-<strong>Interface</strong><br />

power supply when adding an additional network segment (100m max). Each pair of <strong>AS</strong>I1 +/- or <strong>AS</strong>I2 +/- is<br />

connected internally in the <strong>Repeater</strong>.<br />

3. Green LED’s indicating that <strong>AS</strong>-<strong>Interface</strong> power is applied to the corresponding segment.<br />