OverviewGladiator Acoustic Switch SeriesA Higher Level of Performance<strong>Data</strong> <strong>Sheet</strong><strong>Centurion</strong><strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>TDR/GWRFor more information, please visit >www.hawkmeasure.com


Overview<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>Principle of OperationLow power microwave pulses are transmitted along a cable or probe to the product being measured. At the point where the wavemeets the product surface it is reflected by the product. The unit automatically calculates the distance to the pulse reflection usingtime of flight & time expansion. The intensity of the reflection depends on the dielectric constant of the product. The higher thedielectric constant, the stronger the reflection will be e.g up to 80% reflection for water. The instrument measures the time betweenemission and reception of the signal which is proportional to the distance.Contact with the measured product ensures precise accuracy.FunctionPrimary Areas of ApplicationThe <strong>Hawk</strong> range of TDR product are ideal for themeasurement of liquids, powders and granules to a rangeof 35m. This technology is not affected by pressure,temperature, viscosity, vacuum, foam, dust, changes indielectric constant or coating of the probe.• Chemicals• Petrochemicals• Cement• Building Aggregates• Energy• Food & Beverages• Oil & Gas• Pharmaceutical• Pulp & Paper• WastewaterFeatures• Remote, Integral & Smart versions• Up to 35m range (316L cable)• Simple setup• Auto-Calibration to any dieletric• Adjustable Sensitivity• Adjustable signal amplification• Precise & continuous accuracy• 4 wire AC/DC• 2 wire loop• 4-20mA, HART, Foundation Fieldbus, Profibus PA,Profibus DP Devicenet, Modbus, Goshawk• Protection class IP67, NEMA4x• 3G remote communication support• Measures extremely low dielectric (1.4)• Programmable fail safe mode.2


Overview Dimensions<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewAWR Remote Housing111.5 mm (4.4”)192.5 mm (7.6”)174 mm (6.9”)78 mm (3.1”)14 mm (0.6”)30.7 mm (1.2”)7.5 mm (0.3”)192.5 mm (7.6”)147 mm (5.8”)108 mm (4.3”)190 mm (7.5”)107 mm (4.2”)190 mm (7.5”)167.5 mm (6.6”)141.5 mm (5.6”)131.5 mm (5.2”)16.230.033.029.029.033.020.2182.5 mm (7.2”)50 mm (2”)74 mm (2.9”)4 mm (0.2”)147 mm (5.8”)158 mm (6.2”)182.5 mm (7.2”)TDRR / TDRS HousingTDRI Housing110.0 (4.3")85.0 (3.3")M20 cablegland or 3/4"NPT adaptor110.0 (4.3")160.0 (6.3")M20 plugM4groundscrew1 1/2" BSP or NPTmounting thread(2")50.040.0(1.5”)63.0 (2.5") 90.0 (3.5")63.0 (2.5") 195.0 (7.7")1 1/2" BSP or NPTmounting thread40.0(1.5”)3 x M16ConduitEntriesProbe Connection / Cable(2.5")63.040.0(1.5”)1 1/2" BSP or NPTmounting threadProbe / Cable DimensionsA B C D Emm in. mm in. mm in. mm in. mm in.4mm Version 67 2.6 10 0.4 4 0.15 148 5.3 30 1.28mm Version 102.5 4.0 16 0.6 8 0.3 258 10.0 36 1.4ABFGC4mm Version M6x1 sescrew M8x1.25, 20mm deep internal thread8mm Version M8x1 set screw M8x1.25, 20mm deep internal threadCable Length (mm)FDPart NumberStandard Flange / Connection DimensionsA B CStandardmm in. mm in. mm in.FA2 ANSI (Class 150) 120.7 4.75 152.4 6 19.1 0.75FA3FA4EGFD2 ANSI (Class 150) 125 4.9 165 6.5 18 0.7FD3FD4CA BNote: All Flange internal connection threads are 1.5” BSP(fits TB15 units)3


Overview Wiring<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewInputs Model DependantRemote System WiringAWR234AWR2TDRRRELAY 1NCCOMNORELAY 2NCCOMNORELAY 3NCCOMNORELAY 4NCCOMNORELAY 5NCCOMNOTest InCOMMSABShldShld1 2 3 4 5 6 7 8 9 10WhiteBlueRedBlack16 17 18 19 20 21 22 23 24 25 26 27 28 29 307 8 9 10 11 12Is1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ –REDBLACKBLUEWHITETest InBA– +NL11 2 3 4 5 6REDBLACKBLUEWHITE+ –4-20mATRANSDUCER COMMS DC-In AC-In*TRANSDUCER4-20mASinking 4-20mAfrom user deviceORSourcing 4-20mA from Sultan*48VDC Sultan version willhave these terminals markedas the 30-48VDC inputSinking 4-20mAfrom user deviceIntegral System WiringSmart System WiringTDRI234TDRI2TDRS234TDRS2RELAY 1COMMSRELAY 2COMMS1 2 3 4 5 6 7 8 9 101 2 3 4 5 6 7 8 9 10NCCOMNOABShldNCCOMNOABShld+- IS+4-20mAABCOMMS+-DC-In+-HARTL1NAC-In– +Is4-20mATest In–+DC-In– +4-20mATest InSinking 4-20mAfrom user device(max 750ohm)ORSourcing 4-20mAfrom TDRS234(max 250ohm)Sinking 4-20mAfrom user device(max 250ohm)Sinking 4-20mAfrom user deviceORSourcing 4-20mAfrom SultanSinking 4-20mAfrom user device+-Externallypoweredloop(max 750ohm)-IS+InternallySourcedloop(max 270ohm)1. Loop +ve2. Loop -ve3. PE (Protective Earthfor PA/FF only)4. n/a5. Modbus A6. Modbus B7. Modbus Shield (Gndvia capacitor)8. Ground (to enclosure)9. n/a10. n/a4


Overview Part Numbering<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewRemote TransmitterModelAWR2AWR234Remote 2 Wire, No relays, 24VDC onlyRemote 234 Wire, 5 relaysHousingS PolycarbonatePower SupplyB 12-30VDCC 30-48VDC and 48-90VAC (234 units only)U 12-30VDC and 90-260VAC (234 units only)Additional Communications (Modbus, PC comms Gos<strong>Hawk</strong> standard)S Switch only. 5 relays (AWR234 only)X 4-20mA analogueH 4-20mA analogue with HART 2 wire (AWR2 only)I 4-20mA analogue with HART Isolated 4 wire (AWR234 only)A Profibus PAP Profibus DP (AWR234 only)F Foundation FieldbusD Devicenet (AWR234 only)Internal AccessoryX Not AvailableApproval StandardX Not RequiredA22 ATEX Grp II Cat 3 GD T85°C IP67 Tamb -40°C to 70°CAdditional SoftwareX Not RequiredAWR234 S U X X X X5


Part Numbering<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewRemote ProbeModelTDRRRemote TDR ProbeHousingS Mild Steel with glass viewing windowC 316L Stainless Steel with glass viewing windowProcess Temperature1 80ºC (176 f)Probe Type1 4mm 316L stainless steel cable with weight2 8mm 316L stainless steel cable with weightMountingTN15 1.5” NPT ThreadTB15 1.5” BSP ThreadFA2 2” ANSI stainless steel flangeFA3 3” ANSI stainless steel flangeFA4 4” ANSI stainless steel flangeFD2 DIN50 stainless steel flangeFD3 DIN75 stainless steel flangeFD4 DIN100 stainless steel flangeApproval StandardX Not RequiredA22 ATEX Grp II Cat 3 GD T85°C IP67 Tamb -40°C to 70°CCable LengthC100 100 cm (3’3”) flexible cableC200 200 cm (6’7”) flexible cableC300 300 cm (9’10”) flexible cableC500 500 cm (16’5”) flexible cableC1000 1000 cm (12’11”) flexible cableC2000 2000cm (32’10”) flexible cableC3000 3000cm (32’10”) flexible cableC3500 3500cm (32’10”) flexible cableTDRR S 1 1 TB15 X C300Cable (Belden 3084A)CA-TXCC-R-C15 15m cableCA-TXCC-R-C30 30m cableCA-TXCC-R-C50 50m cableCA-TXCC-R-C100 100m cable6


Part Numbering<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewIntegral SystemModelTDRI2 Integral 2 wire TDR ProbeTDRI234 Integral 234 wire TDR Probe, 2 relaysHousingS Valox 374UPower SupplyB 12-30VDCC 30-48VDC and 48-90VAC (234 units only)U 12-30VDC and 90-260VAC (234 units only)Process Temperature1 65ºC ( 150f)Probe Type1 4mm stainless steel cable with weight2 8mm stainless steel cable with weightMountingTN15 1.5” NPT ThreadTB15 1.5” BSP ThreadFA2 2” ANSI stainless steel flangeFA3 3” ANSI stainless steel flangeFA4 4” ANSI stainless steel flangeFD2 DN50 stainless steel flangeFD3 DN75 stainless steel flangeFD4 DN100 stainless steel flangeCommunication (Modbus & PC comms Goshawk standard)X 4-20mA outputH 4-20mA output with HART 2 wire (TDRI2 only)I 4-20mA output with HART 4 wire isolated (TDRI234 only)A Profibus PAF Foundation FieldbusApproval StandardX Not RequiredA22 ATEX Grp II Cat 3 GD T75°C IP67 Tamb -40°C to 65°CCable LengthC100 100 cm (3’3”) flexible cableC200 200 cm (6’7”) flexible cableC300 300 cm (9’10”) flexible cableC500 500 cm (16’5”) flexible cableC1000 1000 cm (32’9”) flexible cableC2000 2000cm (65’7”) flexible cableC3000 3000cm (98’5”) flexible cableC3500 3500cm (115’9”) flexible cableTDRI234 S B 2 TN15 H X C3007


Part Numbering<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewSmart SystemModelTDRS2 Smart 2 wire system (no display or keypad, requires PC with GoshawkII for calibraiton)TDRS234 Smart 234 wire system (no display or keypad, requires PC with GoshawkII for calibraiton)HousingS Mild Steel with glass viewing windowC 316L Stainless Steel with glass viewing windowPower SupplyB 12-30VDC (TDRS234) and 24VDC (TDRS2)Process Temperature1 65ºC ( 150f)Probe Type1 4mm stainless steel cable with weight2 8mm stainless steel cable with weightMountingTN15 1.5” NPT ThreadTB15 1.5” BSP ThreadFA2 2” ANSI stainless steel flangeFA3 3” ANSI stainless steel flangeFA4 4” ANSI stainless steel flangeFD2 DN50 stainless steel flangeFD3 DN75 stainless steel flangeFD4 DN100 stainless steel flangeCommunicationX 4-20mA output with Modbus (TDRS234 only)H 4-20mA output with HART 2 wire (TDRS2 only)Approval StandardX Not RequiredA22 ATEX Grp II Cat 3 GD T75°C IP67 Tamb -40°C to 65°CCable LengthC100 100 cm (3’3”) flexible cableC200 200 cm (6’7”) flexible cableC300 300 cm (9’10”) flexible cableC500 500 cm (16’5”) flexible cableC1000 1000 cm (32’9”) flexible cableC2000 2000cm (65’7”) flexible cableC3000 3000cm (98’5”) flexible cableC3500 3500cm (115’9”) flexible cableTDRS234 S B 1 2 TN15 X X C3008


Part Numbering<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewAccessoriesHAWKLink <strong>Data</strong> ModemModelHLRRemote stand alone HAWKLink systemPower SupplyB 12-30VDCU 12-30VDC and 90-260VACNetwork TypeG3 3G AutobandSim CardS3 Australian Sim Card expires after 3 monthS12 Australian Sim Card expires after 12 monthX Not RequiredHLR U G3 S3HAWKLink USB PC connector for Gos<strong>Hawk</strong>IIHAWKLink-USB9


Specifications<strong>Centurion</strong> <strong>Guided</strong> <strong>Wave</strong> <strong>Radar</strong>OverviewOperating Voltage - 3,4 wire• 12 – 30Vdc (residual ripple no greater than 100mV)• 90 – 265Vac 50/60Hz (remote, integral)• 48Vdc, 48Vac-90Vac 50/60Hz (remote, integral)Operating Voltage - 2 wire & Smart• 14 – 30Vdc (residual ripple no greater than 100mV)• HART 24V @ 250ohmPower Consumption - 3,4 wire•