ItemFunctionCapacityTotal inputIndoor unitOutdoor unitRefrigerant pipingService Ref.Btu/hWkWService Ref.Power supply (phase, cycle,voltage)InputRunning currentkWAStarting current AExternal finish (Panel)Heat exchangerFan (drive) o No.FanFan motor outputkWAirflow (Lo-Mi2-Mi1-Hi) K / min (CFM)External static pressure Pa (mmAq)Booster heaterkWOperation control & ThermostatSound level (Lo-Mi2-Mi1-Hi)dBUnit drain pipe I.D.mm (in.)Wmm (in.)DimensionsDmm (in.)Hmm (in.)Weightkg (lbs.)Service Ref.Power supply (phase, cycle, voltage)Running currentAExternal finishRefrigerant controlCompressorModelMotor outputkWStarter typeProtection devicesHeat exchangerFan (drive) o No.Fan Fan motor output kWAirflowK / min (CFM)Crankcase heaterWDefrost methodSound levelCoolingdBHeatingdBWmm (in.)DimensionsDmm (in.)Hmm (in.)Weightkg (lbs.)RefrigerantChargekg (lbs.)Oil (Model)LPipe size O.D.Liquid mm (in.)Gasmm (in.)Connection methodIndoor sideOutdoor sideBetween the indoor & Height differenceoutdoor units Piping lengthIndoor OutdoorCoolingUpper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚CLower limit D.B. 19˚C, W.B. 15˚C D.B. -5˚CHeatingUpper limit D.B. 28˚C D.B. 21˚C, W.B. 15˚CLower limit D.B. 17˚C D.B. -11˚C, W.B. -12˚CPLA-RP4AA.UKCooling Heating34,100 38,20010,000 (5,000~11,400) 11,200 (5,600~14,000)3.03 3.39PLA-RP4AA.UKSingle phase, 50Hz, 220-230-240V0.25 0.251.25 1.252.0 2.0Munsell 0.70Y 8.59/0.97Plate fin coilTurbo fan (direct) o10.12020-23-26-28 (705-810-920-990)0 (direct blow)—Remote controller & built-in33-36-39-4132 (1-1/4)UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)UNIT : 298 (11-3/4) PANEL : 30 (1-3/16)UNIT : 30 (66) PANEL : 5 (11)PUHZ-RP4VHASingle phase, 50Hz, 220-230-240V12.33 13.94Munsell 3Y 7.8/1.1Linear expansion valveHermeticANV33FDAMT1.9Line startHP switch, LP switch, Discharge thermo.Plate fin coilPropeller (direct) o20.060+0.060100 (3,530)—Reverse cycle4951950 (37-3/8)330+30 (13+1-3/16)1,350 (53-1/8)121 (267)R410A5.5 (12.1)1.4 (MEL56)9.52 (3/8)15.88 (5/8)FlaredFlaredMax. 30mMax. 75mNOTE: 1. Rating conditions (ISO T1)Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)Heating Indoor : D.B. 20: (68˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F)Refrigerant piping length (one way) : 5m (16ft.)2. Guaranteed operating range 3. Above data based on indicated voltageIndoor unitOutdoor unitSingle phase 230V 50HzSingle phase 230V 50Hz8