10.07.2015 Views

TECHNICAL & SERVICE MANUAL Ceiling Cassettes ... - Engvent.ru

TECHNICAL & SERVICE MANUAL Ceiling Cassettes ... - Engvent.ru

TECHNICAL & SERVICE MANUAL Ceiling Cassettes ... - Engvent.ru

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ItemFunctionCapacityTotal inputIndoor unitOutdoor unitRefrigerant pipingService Ref.Btu/hWkWService Ref.Power supply (phase, cycle,voltage)InputRunning currentkWAStarting current AExternal finish (Panel)Heat exchangerFan (drive) o No.FanFan motor outputkWAirflow (Lo-Mi2-Mi1-Hi) K / min (CFM)External static pressure Pa (mmAq)Booster heaterkWOperation control & ThermostatSound level (Lo-Mi2-Mi1-Hi)dBUnit drain pipe I.D.mm (in.)Wmm (in.)DimensionsDmm (in.)Hmm (in.)Weightkg (lbs.)Service Ref.Power supply (phase, cycle, voltage)Running currentAExternal finishRefrigerant controlCompressorModelMotor outputkWStarter typeProtection devicesHeat exchangerFan (drive) o No.Fan Fan motor output kWAirflowK / min (CFM)Crankcase heaterWDefrost methodSound levelCoolingdBHeatingdBWmm (in.)DimensionsDmm (in.)Hmm (in.)Weightkg (lbs.)RefrigerantChargekg (lbs.)Oil (Model)LPipe size O.D.Liquid mm (in.)Gasmm (in.)Connection methodIndoor sideOutdoor sideBetween the indoor & Height differenceoutdoor units Piping lengthIndoor OutdoorCoolingUpper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚CLower limit D.B. 19˚C, W.B. 15˚C D.B. -5˚CHeatingUpper limit D.B. 28˚C D.B. 21˚C, W.B. 15˚CLower limit D.B. 17˚C D.B. -11˚C, W.B. -12˚CPLA-RP4AA.UKCooling Heating34,100 38,20010,000 (5,000~11,400) 11,200 (5,600~14,000)3.03 3.39PLA-RP4AA.UKSingle phase, 50Hz, 220-230-240V0.25 0.251.25 1.252.0 2.0Munsell 0.70Y 8.59/0.97Plate fin coilTurbo fan (direct) o10.12020-23-26-28 (705-810-920-990)0 (direct blow)—Remote controller & built-in33-36-39-4132 (1-1/4)UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)UNIT : 298 (11-3/4) PANEL : 30 (1-3/16)UNIT : 30 (66) PANEL : 5 (11)PUHZ-RP4VHASingle phase, 50Hz, 220-230-240V12.33 13.94Munsell 3Y 7.8/1.1Linear expansion valveHermeticANV33FDAMT1.9Line startHP switch, LP switch, Discharge thermo.Plate fin coilPropeller (direct) o20.060+0.060100 (3,530)—Reverse cycle4951950 (37-3/8)330+30 (13+1-3/16)1,350 (53-1/8)121 (267)R410A5.5 (12.1)1.4 (MEL56)9.52 (3/8)15.88 (5/8)FlaredFlaredMax. 30mMax. 75mNOTE: 1. Rating conditions (ISO T1)Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)Heating Indoor : D.B. 20: (68˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F)Refrigerant piping length (one way) : 5m (16ft.)2. Guaranteed operating range 3. Above data based on indicated voltageIndoor unitOutdoor unitSingle phase 230V 50HzSingle phase 230V 50Hz8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!