10.07.2015 Views

Water-Cooled Condensers - HTS

Water-Cooled Condensers - HTS

Water-Cooled Condensers - HTS

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 14, WGS-AA Chillers Matched with Daikin McQuay ACX (830 RPM) Air-<strong>Cooled</strong> <strong>Condensers</strong>WGSModel130AA140AA160AA170AAWithCondLWT(F)Ambient Air Temperature (F)Ambient Air Temperature (F)With LWT95 105Cond95 105(F)Tons PWR EER Tons PWR EERTons PWR EER Tons PWR EERACX 42 107.2 144.6 8.9 - - - ACX 42 116.1 132.4 10.5 109.3 145.1 9.0100D 44 111.3 146.7 9.1 - - - 160D 44 120.9 133.6 10.9 113.8 146.7 9.3ACX 42 110.6 140.3 9.5 103.4 153.9 8.1 ACX 42 118.3 130.5 10.9 112.0 142.2 9.5110D 44 114.9 142.2 9.7 107.5 155.8 8.3 200D 44 123.1 131.8 11.2 116.7 143.6 9.7ACX 42 112.6 136.7 9.9 105.2 150.4 8.4 ACX 42 120.3 129.0 11.2 114.0 140.6 9.7130D 44 117.0 138.5 10.1 109.5 152.2 8.6 225D 44 125.2 130.2 11.5 118.8 141.9 10.042 115.1 134.3 10.3 107.8 147.9 8.7 (2)ACX42 120.3 121.2 11.9 114.0 132.8 10.3ACX140D 44 119.8 135.7 10.6 112.2 140.5 9.0 110S 44 125.2 122.4 12.3 118.8 134.1. 10.6ACX 42 113.9 160.4 8.5 - - - ACX 42 125.1 144.3 10.4 117.1 159.1 8.8100D 44 118.2 163.0 8.7 - - - 160D 44 130.1 145.9 10.7 121.8 161.0 9.1ACX 42 118.1 155.0 9.1 - - - ACX 42 127.3 141.5 10.8 120.4 155.3 9.3110D 44 122.6 157.4 9.3 - - - 200D 44 132.6 142.9 11.1 125.3 157.0 9.6ACX 42 120.3 150.8 9.6 112.3 165.6 8.1 ACX 42 129.5 139.6 11.1 122.7 153.1 9.6130D 44 125.0 153.0 9.8 116.8 167.9 8.3 225D 44 134.8 140.9 11.5 127.8 154.6 9.942 123.5 147.4 10.1 115.4 162.3 8.5 (2)ACX42 129.5 131.8 11.8 122.7 145.3 10.1ACX140D 44 128.3 149.3 10.3 120.0 164.3 8.8 110S 44 134.8 133.1 12.1 127.8 146.8 10.4ACX 42 125.4 170.8 8.8 - - - ACX 42 137.3 154.5 10.7 128.6 169.4 9.1110D 44 130.3 173.6 9.0 - - - 200D 44 142.8 156.0 11.0 133.9 171.4 9.4ACX 42 128.0 166.1 9.2 - - - ACX 42 140.1 152.7 11.0 131.3 166.5 9.5130D 44 133.0 168.6 9.5 - - - 225D 44 145.7 154.3 11.3 136.8 168.2 9.842 131.5 161.8 9.8 122.9 177.8 8.3 (2)ACX42 140.1 144.9 11.6 131.3 158.7 9.9ACX140D 44 136.7 164.1 10.0 127.9 180.2 8.5 110S 44 145.7 146.5 11.9 136.8 160.4 10.242 133.5 158.0 10.1 124.9 174.1 8.6 (2)ACX42 142.1 142.3 12.0 133.4 155.9 10.3ACX160D 44 138.8 160.1 10.4 130.0 176.4 8.8 130D 44 147.9 143.8 12.3 138.9 157.5 10.6ACX 42 133.6 190.8 8.4 - - - ACX 42 147.3 169.2 10.5 138.2 186.6 8.9110D 44 138.4 193.9 8.6 - - - 200D 44 153.4 171.2 10.8 143.7 188.8 9.1ACX 42 136.6 185.1 8.9 - - - ACX 42 149.6 166.4 10.8 141.4 182.7 9.3130D 44 141.6 188.0 9.0 - - - 225D 44 155.8 168.2 11.1 147.1 184.8 9.642 140.8 179.5 9.4 131.5 197.1 8.0 (2)ACX42 149.6 158.6 11.3 141.4 174.9 9.7ACX140D 44 146.1 182.2 9.6 136.5 199.7 8.2 110S 44 155.8 160.4 11.7 147.1 177.0 10.042 143.2 175.0 9.8 133.8 192.7 8.3 (2)ACX42 151.8 156.0 11.7 143.8 171.5 10.1ACX160D 44 148.7 177.6 10.0 139.0 195.2 8.5 130D 44 157.9 157.3 12.0 149.7 173.4 10.4ACX 42 145.0 204.4 8.5 - - - ACX 42 160.1 179.9 10.7 151.4 199.0 9.1130D 44 150.3 207.8 8.7 - - - 225D 44 166.8 182.2 11.0 157.4 201.4 9.442 149.8 197.5 9.1 - - - (2)ACX42 160.1 172.1 11.2 151.4 191.2 9.5ACX140D 44 155.4 200.6 9.3 - - - 110S 44 166.8 174.4 11.5 157.4 193.6 9.8190AA42 152.6 192.3 9.5 142.7 211.2 8.1 (2)ACX42 161.9 168.1 11.6 154.1 187.0 9.9ACX160D 44 158.3 195.2 9.7 148.1 214.0 8.3 130D 44 168.4 170.2 11.9 160.4 18.2 10.242 157.8 184.6 10.3 147.7 203.9 8.7 (2)ACX42 164.5 165.9 11.9 156.6 184.5 10.2ACX200D 44 163.9 187.3 10.5 153.5 206.4 8.9 140D 44 171.0 162.8 12.2 163.0 186.6 10.5NOTES:1. Power and EER include unit, condenser fans and control power.2. Performance may be interpolated between values given in the table.3. The notation (2) ACX 130D indicates that two ACX 130D condensers are used, one per WGS circuit. Each condenser hastwo refrigerant circuits that must be manifolded together in the field.4. A relief must be field installed in the discharge piping.5. The ratings in this catalog are consistent with the McQuayTools selection program version shown inside front cover. Forthe most up-to-date information, please go to www.daikinmcquay.com.Catalog WGS-1 WGS 130A – 190A 25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!