phase-out date. It has the best toxicity and flame propagation rating under ASHRAE Std 34 safetystandard.User Friendly MicroTech II ControlsThe MicroTech II unit controller provides an easy-tousecontrol environment. The control logic is designedto provide maximum efficiency, to continue operation inunusual operating conditions, and to provide a historyof unit operation.Perhaps the greatest benefit is Daikin McQuay’s OpenChoice feature, which allows easy integration with yourbuilding automation system of choice using LONTALK,BACnet or Modbus standard protocols. See thecomplete control description on page 8 in this catalog.MicroTech II control uses distributed control, with eachrefrigerant circuit having a dedicated microprocessor.Distributed control architecture means that if anycompressor controller is unavailable, the remaining controllers are unaffected and their compressors willcontinue to operate. This feature can greatly enhance chiller reliability.Installation Savings for Retrofit ApplicationsAll WGS chillers will fit through a 36-inch-wide door (without sound enclosure). This attribute can meanconsiderable installation cost savings on many retrofit applications that may have access problems.<strong>Water</strong>-<strong>Cooled</strong> <strong>Condensers</strong> (AW Models)A separate water-cooled condenser is provided for eachrefrigerant circuit. They are cleanable, shell-and-tube typewith water in the tubes and refrigerant in the shell side. Eachcondenser circuit is capable of holding the circuit'srefrigerant charge and each circuit has its own charging andrelief valves. They are designed, constructed and tested inaccordance with the ASME Pressure Vessel Code. Optionalcondenser water manifolds (as shown on the right) areavailable to provide a single piping connection to the inletand outlet.The condensers are constructed with a carbon steel shell andseamless, integrally finned, high efficiency copper tubes, roller expanded into steel tubesheets. The waterheads are removable and have vent and drain connections at each end. Also included is a liquid shutoffvalve, purge valve, and relief valve per ANSI/ASHRAE Pressure Vessel Code, Section VIII.<strong>Water</strong> side working pressure is 225 psi (1551 kPa); refrigerant side is 350 psi (2413 kPa).Catalog WGS-1 WGS 130A – 190A 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!