10.07.2015 Views

Water-Cooled Condensers - HTS

Water-Cooled Condensers - HTS

Water-Cooled Condensers - HTS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

High Short Circuit Current Rated Panel, Multi-PointA high short circuit rated panel with high interrupt current rated disconnect switches for eachcircuit, properly sized for model and voltage required. The high short circuit rated panel meansthat a short circuit current up to the ratings shown in Table 36 will be contained in the panel.There is a short period of time when the circuit breaker will pass a short circuit before opening acircuit that can damage downstream components. In other words, the enclosure is stronger thana standard enclosure. No compressor isolation circuit breakers are included.Power Block, Single PointConnection to a single power block with compressor isolation circuit breakers for each circuit.The circuit breakers are only accessible when the panel door is opened. No disconnect switches.Disconnect Switch, Single PointConnection to a single disconnect switch with compressor isolation circuit breakers for eachcircuit. The circuit breakers are only accessible when the panel door is opened.High Interrupt Disconnect Switch, Single PointA high interrupt current rating, non-fused disconnect switch with through-the-door handle. Thedisconnect switch is properly sized for model and voltage required. Compressor isolation circuitbreakers for each circuit are included. The circuit breakers are only accessible when the paneldoor is opened.High Short Circuit Current Rated Panel, Single PointA high short circuit rated panel with a single disconnect switch, properly sized for model andvoltage required. The high short circuit rated panel means that a short circuit current up to theratings shown in Table 36 will be contained in the panel. There is a short period of time whenthe circuit breaker will pass a short circuit before opening a circuit that can damage downstreamcomponents. In other words, the enclosure is stronger than a standard enclosure. Compressorisolation circuit breakers for each circuit are included. . The circuit breakers are only accessiblewhen the panel door is opened.Table 35, Power Connection OptionsMulti-Point (Code) Single Point (Code)Power Block STD (MN) OPT. Incl CB (PC)Disconnect Switch(s) OPT, No CB (WN) OPT, Incl CB (DC)High Interrupt Disconnect Switch. OPT, No CB (WT) OPT, Incl CB (DT)High Short Circuit Rated Panel OPT, No CB (WH) OPT, Incl CB (DH)NOTE:1. CB = Compressor isolation circuit breaker2. (Code) is the Daikin McQuay ordering codeTable 36, Interrupt Ratings (KA)Select OnlyOne of TheseOptions208V 230V 380V 460V 600VStandard Short Circuit Rating 35 35 35 35 10High Interrupt Rating Disconnect Switch (1) 200 200 100 100 25High Short Circuit Rating Panel (2) 65 65 65 65 25NOTES:1. High Interrupt Rating Disconnect Switch is for only the disconnect switch.2. High Short Circuit Rating (HSCCR) Panel includes high interrupt rating disconnect switch(es).115-Volt Convenience OutletProvides a 115-volt power source on the unit for service equipment.52 WGS 130A – 190A Catalog WGS-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!