11.07.2015 Views

Annual Report 2009-10 - United Breweries Limited

Annual Report 2009-10 - United Breweries Limited

Annual Report 2009-10 - United Breweries Limited

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

STATEMENT UNDER SECTION 217(1)(e) OF THE COMPANIES ACT, 1956A. Conservation of EnergyEnergy conservation measures taken by the Company:Annexure to Directors’ <strong>Report</strong>Electrical Energy– Vapour absorption machine is being commissioned at Bangalore unit for generating chilled water for wort cooling insteadof using high electricity consuming reciprocating compressors.– Draft control on alternate fuel boilers installed to reduce electricity consumption at Palakkad, Orissa & Mangalore units.– Lighting energy savers installed at Mumbai, Bangalore & Mangalore units.– Focus on optimal work in process during the off season has reduced refrigeration load and consequently saved on energyconsumption.– Installed variable frequency drives in Mumbai on high load motor to reduce energy consumption.– De-superheaters in Refrigeration compressor installed at Bangalore, Kalyani & Palakkad units to reduce electricityconsumption.– Chilled water generation through CO 2evaporation implemented at Mumbai to reduce electrical consumption.Fuel Oil Consumption– De-superheaters installed at Bangalore, Palakkad and Kalyani units to generate higher feed water temperature in boilersleading to reduced solid fuel consumption.– After successful implementation of alternate fuel boilers at units located at Punjab, West Bengal and Andhra Pradesh,alternate fuel boilers are installed at all units except at Cherthala and Goa. This has reduced fuel cost substantially.Water Conservation– Recycling of effluent treated water with programmable logic control operated reverse osmosis plant installed at Mallepally,and Ludhiana units to ensure water conservation.– Rainwater harvesting initiative is being undertaken at Mallepally unit in a phased manner to save water and enhancethe ground water table.Environment– LED coupled with solar power & geo thermal office cooling system installed at Mallepally unit. Vapor Heat recoverysystems are installed at Mumbai & Mallepally units.– Heat recovery system installed in Mumbai to reduce fuel consumption and reduce heat emission into the atmosphere.This has a positive impact on reduction in global warming.– Commissioned CO 2recovery plant at all units. This has reduced release of green house gases into atmosphere.B. Technology Absorption– First Mash filter & high speed 36000 BPH bottling line commissioned at Mallepally unit in Andhra Pradesh.– Coil cooler installed for Diesel Generator (DG) sets at Mallepally unit in place of Radiators to increase efficiency of DGsets during longer running hours at high temperature regions.– Latest technology in labellers, Auto PU controlled Pasteurizer and fillers for beer packaging has been implemented atMallepally. This has resulted in improved quality, reduced wastages and higher productivities on the line.– Double Evacuation Filler commissioned in Cherthala unit.– Automation and Auto Blowdown installed in the boilers on selective basis.C. Research and DevelopmentThe Company has continued its Research & Development (R&D) programme in the area of development of two row maltingvariety of Barley. The Company is expecting to shortly launch a flavoured beer in the market by utilizing the technologydeveloped by our R&D department.8D. Foreign Exchange Inflow and Outflow (Rs. in Million)Foreign Exchange earned : 9.42Foreign Exchange used : 738.30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!