11.07.2015 Views

Directional Control Air Valves & Accessories

Directional Control Air Valves & Accessories

Directional Control Air Valves & Accessories

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BIG BAZOOKA ORDERING INFORMATIONEXAMPLEBB 331 - 301 - 20 - 2 - 120V / 60HzPILOT VALVEOPERATORS• SINGLE SOLENOIDspring returnmaintained contact.................. 331• DOUBLE SOLENOID(Momentary Contact).............. 332AIR PILOTspring return(Maintained Contact)............... 031DOUBLE AIR PILOT(Momentary Contact).............. 032• LOC-MASTER SafetyBleed Valve ............................. 045• SINGLE SOLENOIDExplosion Proof(Maintained Contact)............... 421• DOUBLE SOLENOIDExplosion Proof(Momentary Contact).............. 422MAIN VALVEOPTIONS2-WAY - Normally Closed(3 Port Plugged)............................................. 202-WAY - Normally Open(3 Port Plugged)............................................. 213-WAY - Normally Closed............................. 313-WAY - Normally Open................................ 323-WAY - Selector Valve.................................. 333-WAY - <strong>Directional</strong> Valve............................. 34See Piping InstructionsMAIN VALVE• Minimum Orifice.... 2.06 inches• Valve may be mounted in any position• Maximum Operating Pressure..... 125 psig• Minimum Operating Pressure...... 30 psig• Media..... <strong>Air</strong> onlyExternal Pilot Available for LowPressure/Vacuum Applications (specify)SOLENOID DATAPilot Operated coils with self compensatingplungers. Solenoid Assembly guaranteed forlife of valve.P.S.I.GCv = 45 70 - 2150 S.C.F.M.67Inrush CurrentHolding Current120/60.11 amps.068 ampsOther voltages and explosion proof models availablePORT SIZEDESIGNATION1-1/2 NPTF...................... 152 NPTF............................ 202-1/2 NPTF...................... 25ACCESSIORIES& OPTIONSMANUAL OVERRIDE-Non Locking-Solenoid Models Only..................... 1Manual Override-Locking Type.................................... 2External Pilot (for Vacuum & LowPressure applications)............. specifyVoltage & Cycles..................... specifyStandard 1= 120/60 4= 240/60Voltages 2= 12VDC 5= 24VDC3= 24/60 6= 120VDCOther voltages & explosion proof models available.PIPING ARRANGEMENTSAPPLICATION PORT #1 PORT #2 PORT #33-WayNormallyClosedSupply Outlet Exhaust3-WayNormallyOpenSupply Outlet Exhaust2-WayNormallyClosedSupply Outlet Plugged2-Way NormallyOpenSupply Outlet Plugged<strong>Directional</strong> Valve Closed Supply Open(requires external pilot) OutletOutletSelector Valve Supply Outlet Supply(requires external pilot)Loc-Master Supply Outlet Exhaust

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!