Infinity E-3 Operating <strong>Manual</strong> Page 19Pressure SenderVDO: Standard VDO pressure senders (as fitted to a Rotax 912/914 engine)VDO pressure senders used to measure fuel pressure require the fuel isolation kitavailable from VDO.Linear pressure senders: Linear types with a 0V-5V range are supported, pullupresistor in instrument is 1k5 Ohms.Pressure sensorsUser defined senders: The E-3 has a user sender calibration feature that can becustomized for senders not listed above.VDO Bar/Resistance curve for a 10 Bar pressure senderRange8 to 30V DCResolution 0.1VPressure(Bar)Supply Voltage MeasurementResistance(Ohms)0 102 514 866 1228 15210 180