M<strong>203</strong> <strong>Loewe</strong> <strong>Re</strong>:<strong>connect</strong><br />

Changing the <strong>Loewe</strong> IR code at the television<br />

In order to avoid IR conflicts between the <strong>Loewe</strong> television and the<br />

<strong>Re</strong>vox system, the system address at the <strong>Loewe</strong> television and the<br />

remote control must be changed. The reason for this is as follows:<br />

Both <strong>Re</strong>vox and <strong>Loewe</strong> use an RC5 code with the system address 00<br />

for the television. For this reason, both systems will react to some of<br />

each other’s commands. This IR conflict can be solved if the system<br />

address 02 is selected for the <strong>Loewe</strong> television, instead of the 00.<br />

The system address is changed in the following way:<br />

At the <strong>Loewe</strong> television (board operating element):<br />

� Press the M button briefly<br />

� Press the - button briefly<br />

Then, at the <strong>Loewe</strong> Assist 1 remote control:<br />

� press the MENU button within 1 second<br />

Now, the service menu should be visible. Select the sub-menu “Other<br />

adjustments” from this menu. Select the menu “RC subsystem” from<br />

the “Other adjustments” menu. The factory setting for the “RC<br />

subsystem” menu is to set the system address to 00. Now set this to<br />

02.<br />

The <strong>Loewe</strong> TV now reacts to the system address 02 as well as to the<br />

originally set 00.<br />

14