11.07.2015 Views

RescueNet Code Review Utilities - ZOLL Data Systems

RescueNet Code Review Utilities - ZOLL Data Systems

RescueNet Code Review Utilities - ZOLL Data Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DocumentationConfiguring case transfer settings<strong>RescueNet</strong> <strong>Code</strong> <strong>Review</strong> - <strong>ZOLL</strong> <strong>Data</strong> Relay and <strong>ZOLL</strong> <strong>Data</strong> Retriever • 29Chapter 2 Transferring cases via <strong>ZOLL</strong> <strong>Data</strong> Retriever: Configuring case transfer settingsWhen you create a new case from a card reader, a serial connection, or Bluetooth, thetransfer is controlled by the settings on the associated Options tab.InfraredUSB or internal infrared readers are recommended for Windows 2000 and later. Noconfiguration is required here.Card reader• Internal. Choose Generic for internal card readers such as what is installed innotebook PCs. The memory location can be found automatically by a tool available in<strong>RescueNet</strong> <strong>Code</strong> <strong>Review</strong>. Launch <strong>RescueNet</strong> <strong>Code</strong> <strong>Review</strong>. Go to Tools > Options >Card Reader. Click Detect to find the first free memory window. Copy the selectedmemory window. Now go back to <strong>ZOLL</strong> <strong>Data</strong> Retriever Options and paste that memorywindow in the memory location field.• External. Choose External for the OmniDrive Pro, OmniDrive USB LF, and theOmniDrive USB Intern Pro.You can optionally choose to have cards be erased automatically after they have beensuccessfully read. This makes it possible to use the card next in either an M Series/ESeries or 1600/1700 defibrillator.BluetoothThe defibrillator baud setting in <strong>ZOLL</strong> <strong>Data</strong> Retriever must match what is configured in thedefibrillator (see your defibrillator manual for details).SerialThe COM port must match that used on the PC by the serial device. The defibrillator baudsetting in <strong>ZOLL</strong> <strong>Data</strong> Retriever must match what is configured in the defibrillator (see yourdefibrillator manual for details).• For the M Series/E Series, the default setting is 115200.• For the 1600/1700, the default setting is 57600.269 Mill RoadChelmsford, MA 01824-4105800-348-9011 Toll Free978-421-0025 Faxwww.<strong>ZOLL</strong>.comLatest docs: www.zolldata.com/documentation/

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!