11.07.2015 Views

Tender Notice

Tender Notice

Tender Notice

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

101112131415161718Page 36Clause 2.5Page 37Clause 3.2Page 37Clause 3.7Page 37Clause 3.11Page 38Clause 6.3Page 38 - 39Clause 6.5Page 41Clause 10.18Page 42Clause 12.3Page 49Clause 27.1(cage bottom) from the Ground and theHorizontal Working outreach shall not beless than 25 - 30 mtrsThe gearbox shall be fully automatictransmission type. (Allison)Height to working cage bottom : 68metersSWL with monitor in the cage Delivery upto 3500 LPM : 300 KgsMaximum C/C width of the vehicle whenJacks are fully extended on both sides :7.0 meters…there shall preferably a third boom withvertical movement of approx. 130degrees to enable a person climb downfrom the cage to the ladder on the secondboom.The first boom shall be able to elevate inthe range of approx. –3 degree to +85degree angleIn addition, the following controls shall beprovided on jack control panel: A fullfunctional cordless remote with a 100metres range to be provided for the allboom and water monitor movements,except for auto levelling system.The cage shall be designed for 500 Kgworking load and shall be tested with 25%dynamic overload.The system shall incorporate simple testscreens to enable testing of the workingcage and the turntable control panels.The tests shall also cover display unit,push buttons, joysticksthe Ground and the Horizontal workingoutreach with 500 Kg Cage Load shall not beless than 25 meters.Please remove “Allison” since Volvo andMercedes Benz may wish to provide their ownAutomatic Transmission Systems.Please confirm that the cage bottom height of68 meters shall be available with full safeworking load of 500 Kgs. No reduction inworking load from 500 Kgs shall be acceptablefor 68 meter cage bottom height when nomonitor is operatingWe request you to modify it to 150 Kgs.This may be modified to Max of 9.0 meters.Higher jacking spread is desired for a heavierunit in order to ensure stability at maximumheight.Since the 70 meter units do not have ladder,the words ”to enable a person climb downfrom the cage to the ladder on the secondboom” may please be deleted.Please modify it to 0 to +85 degrees providedall the other parameters are achieved.We do not understand why a very importantfeature such as ’Auto Levelling’ is to be left outof the Cordless Remote Control. Any reputedmanufacturer must be able to provide thisfeature on the cordless remote control.Out of all other functions, the Auto LevellingFunction is the utmost function that requires aCordless Remote Control. Hence the word’except for’ must be replaced with ’including’Please include “Under no circumstances –except when the monitor is operational –reduction in cage load capacity shall beallowed in the working envelope. i.e. the safeworking load of 500 Kgs when monitor is notrunning must be available even at 68 metercage bottom height (i.e. when all the boomsand jibs are fully extended)Vema Control Systems are 'SELF DIAGNOSTICFULL FEEDBACK' Systems. This means thatwhen a component like a Joystick, Push Buttonetc fails, the indication immediately is shownon the main display. Hence, our system doesnot require any test screens for testing of suchcomponents. Please confirm this is acceptable.shall not be less than68 mtrs (cage bottom)from the Ground andthe Horizontal Workingoutreach shall not beless than 25 - 30 mtrs“The gearbox should befully automatic typewith torque convertor”or Automated ManualTransmission (AMT)No change is required.No change is required.Maximum C/C width ofthe vehicle when Jacksare fully extended onboth sides : 8.0 metersThis clause is deleted.No ChangeNo ChangeThe testing of the cageshall be as perparameters specified inthe standards inDynamic and staticconditionsThe system shallincorporate simple testscreens to enabletesting of the workingcage and the turntablecontrol panels. Thetests shall also coverdisplay unit, push

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!