11.07.2015 Views

Tender Notice

Tender Notice

Tender Notice

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

252627282930Clause 6.5Page 39Clause 10.3Page 40Clause 10.18Page 41Clause 11.3Page 42Clause 12.1Page 42Clause 12.9Page 43extensions providing direct movementand the other articulated boom withvertical movement of approx. 180degrees, there shall preferably a thirdboom with vertical movement of approx.130 degrees to enable a person climbdown from the cage to the ladder on thesecond boom. The other booms shallprovide an up-and-over capability ofapprox. 12.5 m throughout its verticalmovement.The first boom shall be able to elevate inthe range of approx. –3 degree to +85degree angle.Each wheel shall be provided with offgroundsensorsJack control panel :10.18.11 All boom movements and allmonitor movementsThe electronic system shall be approvedaccording to the valid standards anddirectives. The system shall be EMCtested (EU directive 89/336/EEC) and CEtype tested by appropriate agency.12.1 (Pg 42) The working cage shall befixed to the third articulated boom(optional), in such a way that there is asafe and easy way to and from the boomladders through an inward opening doorof the cage rear side. No climbing overthe cage railing will be allowed. Theworking cage should fully comply with thesafety requirement of EN1777 & EN 280.12.9 (Pg 43) : The dimensions of therescue platform shall be approx. 1.2 m x0.6 mportions are not relevant.The up and over capacity is 11,0 m. Pleaseamend.In F70 RPX this is 0 to 83 degree and all theperformance parameter are met. According toour opinion the range of the 1st boom shouldbe deleted or changed from 0 to 83 degrees.In Bronto F70 RPX, it is a built-in safetymechanism in the outrigger operation that ischecking that the wheels are off the groundand only then allowing the boom movements.The safety feature as required by you is therebut in a different way. Please accept andamend.Boom and monitor movements are notallowed from jack side control panel. Pleasedelete 10.18.11.okHere it has been referred to an old standard, itshould be 95/54/EC:1995 instead of89/336/EEC.Third boom need not be mentioned again andagain as it is two or three boom.There are no boom ladders.EN 280 does not apply.Bronto units the dimension are 1.36 x 0.5 m.Kindly amend.main boom withtelescopic extensionsproviding directmovement and theother articulated boomwith vertical movementof approx. 180 degrees,there shall preferably athird boom withvertical movement ofapprox. 130 degrees.The other booms shallprovide an up-and-overcapability of approx.12.5 m throughout itsvertical movement.”Approx mean +/- 10%No ChangeEach wheel shall beprovided with offgroundsensors or thejack legs shall haveground pressuresensors and systemshould not allow to liftthe booms unless thereis enough groundpressure on jacks andvehicle is correctlylevelled.No ChangePlease confirmChanged “The workingcage shall be fixed tothe boom. The workingcage should fullycomply with the safetyrequirement of EN1777or any other standardsas the case may be.The approx. dimensionsof the rescue platformshall not be less than1.25 m length X 0.5 mwidth.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!