NS5<strong>00</strong>0/6<strong>00</strong>0 <strong>Handler</strong> Interface Manual for the Catalyst Test SystemNoteBe sure to leave the V-grooves attached to the spacers.7) Attach one of the circular spacers marked A, B, or C (pn 480-049-<strong>00</strong>, 01, 02) to amatching position on the interface plate assembly using the 1/4"-20 captive screws ineach spacer (see Figure 16).Adaptive Spacer(PN 480-049-XX)Native Groove Spacer(with V-groove attached)Guide Pin(PN 480-018-02)Adaptive Guide Pin Spacer(PN 480-051-<strong>00</strong>)Figure 16 Adaptive Guide Pin and Spacer Attachment8) Fasten the V-groove/spacer assemblies to the matching adaptive spacers. See KCS andManipulator Manual (553-7<strong>00</strong>-78).9) Remove the guide pins from the interface assembly plate.10) Attach the two guide pin spacers (pn 480-051-<strong>00</strong>) to the interface assembly plate.11) Tighten the guide pin spacers until they are snug.12) Fasten the guide pins to the adaptive guide pin spacers.13) Tighten (torque: 24 inch-lbs) the guide pins.22