11.07.2015 Views

E-SAFE® II Hybrid Power Switch User Manual Rev C June ... - Watlow

E-SAFE® II Hybrid Power Switch User Manual Rev C June ... - Watlow

E-SAFE® II Hybrid Power Switch User Manual Rev C June ... - Watlow

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

L3240VÅ L2L1FuseBreakerSeries SDSD3_-_K_ _-_ _RG1 2 3 4 5 68 9 1011ResetFuseSeries LVLVC6KW-4542500A12673849510Fuse240VÅ120VÅFuseFuseFuseCR1A1 Input A2T1 T2 T3120VÅ 2 4 6CR1Coil7L11L23L35ControlThermocoupleHigh LimitThermocoupleE-SAFE ® <strong>II</strong><strong>Hybrid</strong> <strong>Power</strong><strong>Switch</strong>ES2X-2XX0-0000DeltaConnectedHeaterT3T3NT2T14-Wire WyeConnected HeaterWyeT2T1ConnectedHeaterNeutralL3480VÅ L2L1FuseResetBreaker120VÅSeries SDSD3_-_K_ _-_ _RG1 2 3 4 5 68 9 101112345FuseFuseSeries LVLVC6KW-4542500A678910480VÅFuseFuseFuseCR1A1 Input A2T1120VÅ 2CR1Coil7L11L23T24L35T36ControlThermocoupleE-SAFE ® <strong>II</strong><strong>Hybrid</strong> <strong>Power</strong><strong>Switch</strong>ES2X-3XX0-00004-Wire WyeConnected HeaterHigh LimitThermocoupleSystem Wiring Example 240 volt, 3-phase, 3 polewith ac input controlNote:ES2X-2XX0-0000 is powered via L1, L2System Wiring Example 277/480 volt, 3-phase, 3pole with ac input control, 4-wire Wye connectedheater onlyNote:ES2X-3XX0-0000 is powered via terminal (7) and L1N120VÅ L1FuseBreakerSeries SDSD3_-_K_ _-_ _RG1 2 3 4 5 6Fuse8 9 10117CR1L11InputA1 A2T1120VÅ 2L23T24L35T36E-SAFE ® <strong>II</strong><strong>Hybrid</strong> <strong>Power</strong><strong>Switch</strong>ES21-1HV0-0000240VÅ L2L1FuseBreakerSeries SDSD3_-_K_ _-_ _RG1 2 3 4 5 6891011FuseFuse240VÅ120VÅFuseCR1Input120VÅ7L11L23L35A1 A2T1 T2 T32 4 6E-SAFE ® <strong>II</strong><strong>Hybrid</strong> <strong>Power</strong><strong>Switch</strong>ES22-2HV0-0000ResetSeries LVLVC6KW-4542500A12345678910FuseFuseCR1CoilControlThermocoupleHigh LimitThermocoupleResetSeries LVLVC6KW-4542500A12345678910FuseFuseCR1CoilControlThermocoupleHigh LimitThermocoupleSystem Wiring Example 120 volt, single-phase, 1pole with ac input controlSystem Wiring Example 240 volt, single-phase, 2pole with ac input controlç∫WARNING:Wiring must conform to National Electric Code (NEC) safety standards, as well as locally applicable codes. Failure to do so could result inpersonal injury or loss of life. See the product rating curve for wire gauge selection, ambient temperature and current restrictions.∫WARNING:Only authorized and qualified personnel should install and service the E-SAFE <strong>II</strong> <strong>Hybrid</strong> <strong>Power</strong> <strong>Switch</strong>. Failure to comply with these recommendationsmay result in damage to equipment and property and injury to personnel.Torque Guidelines:Properly torque line and load terminals to 2.25 nm (20 in-lbs).NOTE:Do not use an RC snubber on the temperature control command signal output. The leakage current througha snubber circuit can turn the E-SAFE <strong>II</strong> relay on, even when the command signal is off.SnubbersSnubbers Snubbers

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!