MANAGEMENT PACKETSM01 Set <strong>PINpad</strong> Mode• Master Session PIN encryptions are limited to 4 within 120 seconds. If a5th PIN encryption is attempted within the 120 seconds, the <strong>PINpad</strong> willprompt with a message 'PLS WAIT' until the 120 second timer has expired<strong>and</strong> then continue with the encryption.3 If the <strong>PINpad</strong> mode is changed all keys are erased:• KLK erased• All Master Keys erased• All DUKPT Keys erased• See defaults in 2a above• 1 DES mode for MS <strong>and</strong> all DUKPT engines• DUAL Mode (MASTER+DUKPT)4 Power On Display• At power on,• In PP1000 mode, the unit will display: PP1000 TDES 4E300xx MM/YY• In PP1000se mode, the unit will display: PP<strong>1000SE</strong> TDES PEDCERTIFIED 4E300xx MM/YY5 Display Mode, FW Version <strong>and</strong> FW Date• Pressing the cancel key (RED) immediately followed by the ‘1’ key willdisplay the following until the cancel key (RED) is pressed or a packet isreceived.• In PP1000 mode, the unit will display: PP1000 TDES 4E300xx MM/YY• In PP1000se mode, the unit will display: PP<strong>1000SE</strong> TDES PEDCERTIFIED 4E300xx MM/YY.28 PINPAD <strong>1000SE</strong> REFERENCE AND PROGRAMMERS GUIDE