ENVELOPE <strong>CON</strong>TROL GUIDELINES<br />

SE<strong>CON</strong>DARY SETTLEMENTS<br />

Key Elements Type I Infill<br />

Development<br />

A. Building Height* The overall scale of the main<br />

building fronting the road, in<br />

terms of the springing line, roof<br />

ridge or top of the roof parapet<br />

where applicable, is to match<br />

that of the adjacent conserved<br />

buildings. If the adjacent<br />

conserved buildings have<br />

different heights, the higher<br />

building forms the basis of the<br />

height control. See Figure 1<br />

The rear can be developed up<br />

to the maximum number of<br />

storeys allowable within the<br />

respective areas. The floor-tofloor<br />

height of the rear is to<br />

comply with Development<br />

Control guidelines. See Figure 2<br />

B. Setback* Front façade of the building is to<br />

line up with the adjacent<br />

conserved buildings.<br />

The rear is to be set back to the<br />

rear service road widening line.<br />

PART 3 PLANNING PARAMETERS AND<br />

RESTORATION GUIDELINES<br />

ENVELOPE <strong>CON</strong>TROL GUIDELINES<br />

Type II Infill &<br />

Independent<br />

Development<br />

Development can be up to the<br />

maximum number of storeys<br />

allowable within the respective<br />

areas.<br />

The floor-to-floor height is to<br />

comply with Development<br />

Control <strong>Guidelines</strong>.<br />

The road reserve lines and<br />

current Development Control<br />

setback requirements are<br />

applicable.<br />

C. Roof* Form and material can vary Form and material can vary<br />

D. Front Facade Design and material can vary. Design and material can vary.<br />

D1. Covered<br />

Walkway*<br />

Colonnaded covered walkway is<br />

to be provided to maintain the<br />

continuity of the streetscape.<br />

The width and height are to<br />

match that of adjacent<br />

conserved buildings and the<br />

soffit height cannot exceed<br />

3.6m.<br />

The floor level is to match that<br />

of the adjacent conserved<br />

building. Where the difference<br />

in level is not more than<br />

175mm, a ramp is to be<br />

provided. The gradient of the<br />

ramps cannot be steeper than<br />

1:10.<br />

The flooring can be of any<br />

material provided it does not<br />

have a highly polished gloss<br />

finish.<br />

Covered walkway is to be<br />

provided to maintain the<br />

character of the streetscape.<br />

The width and height of covered<br />

walkways are to comply with<br />

Development Control<br />

guidelines.<br />

The floor level is to match that<br />

of open walkway.<br />

DEC 2011