Anti-Extruder function. This function reducesthe heating temperature to 57°C in the case thatdomestic hot water circulation is detected in theheating mode.Activate anti-extruder functionRange of values which canbe seton (Standard setting) - oFParameterP3Domestic hot water post circulation functionWith the post circulation function active afterdomestic hot water flow, the pump remains onfor 2.5 seconds in winter time and 1.5 secondsin summer time to reduce the formation oflime scale.Activate domestic hot water post circulationRange of values which canParameterbe seton (Settaggio di serie) - oFP4Heating power. The Eolo Star <strong>24</strong> 3 E boiler is fittedwith an electronic modulation which adaptsthe power of the boiler to effective heat requestsof the home. Then the boiler works normally in avariable gas pressure field between the minimumheating power and the maximum heating powerdepending on the system’s heating load.N.B.: The Eolo Star <strong>24</strong> 3 E boiler is produced andcalibrated in the heating phase to the nominalheat output. Approximately 10 minutes are neededto reach the nominal heat output changeableusing parameter (P6).N.B.: the selection of the “Minimum heatingpower” and “Maximum heating power” parameters,in the presence of a heating request, allowsswitch-on of the boiler and power supply of themodulator with current equal to the value of therespective set value.Minimum heating powerRange of values which canbe setfrom 0 % Imax. to 63 % Imax.Maximum heating powerRange of values which canbe setfrom 0 % Imax. to 99 % Imax.(Standard setting)ParameterP5ParameterP6Timer setting. The boiler has an electronictiming device that prevents the burner fromigniting too often in the heating phase. The boileris supplied as per standard with a timer adjustedat 3 minutes.Heating ramp timing. The boiler performs anignition ramp of about 10 minutes to arrive fromminimum power to nominal heating power.Heating ramp timingRange of values which canbe setfrom 1 to 101 = 30 seconds2 = 2 minutes10 = 10 minutes (Standardsetting)ParameterP83.8 AUTOMATIC SLOW IGNITIONFUNCTION WITH TIMED RAMPDELIVERY.In the ignition phase the P.C.B. carries out anincreasing gas delivery ramp (with pressure valuesthat depend on the type of gas selected) withpreset duration. This prevents every calibrationor precision adjustment of the boiler ignitionphase in any conditions of use.3.9 “CHIMNEY SWEEP FUNCTION”.When activated, this function forces the boilerat max. output for 15 minutes.In this state all adjustments are excluded andonly the temperature safety thermostat and thelimit thermostat remain active. To activate thechimney sweep function, press the Reset key forat least 10 seconds with the boiler on stand-by. Itsactivation is indicated by the flashing symbols (8and 11 Fig. 2-1). This function allows the technicianto check the combustion parameters. Afterthe checks, deactivate the function switching theboiler off and then on again.3.10 HEATING TIMER.The Eolo Star <strong>24</strong> 3 E boiler has an electronictiming device that prevents the burner fromigniting too often in the heating phase. The boileris supplied as per standard with a timer adjustedat 3 minutes. To adjust the timer values, followinstructions for parameter settings by selectingparameter (P7) and set it with one of the valuesindicated on the relative table.3.11 PUMP ANTI-BLOCK FUNCTION.In summer function mode ( ) the boiler has afunction that starts the pump at least once every<strong>24</strong> hours for the duration of 30 seconds in orderto reduce the risk of the pump becoming blockeddue to prolonged inactivity.In winter function mode ( ) the boiler has afunction that makes the pump start at least onceevery 3 hours for 30 seconds.3.12 FUNZIONE ANTITRAFILACIRCUITO SANITARIO.This function reduces the heating temperatureto 57°C if the domestic hot water circulation isdetected in the heating mode. The function canbe excluded using parameter (P3).3.14 P.C.B. PERIODICAL SELF-CHECK.During functioning in heating mode or withboiler in standby, the function activates every 18hours after the last boiler check/power supply. Incase of functioning in domestic hot water modethe self-check starts within 10 minutes after theend of the withdrawing in progress, for durationof approx. 10 seconds.N.B.: during self-check, the boiler remains off,including signalling.INSTALLATORUSERTECHNICIANHeating ignitions timerRange of values which canbe setfrom 1 to 101 = 30 seconds2 = 2 minutes3 = 3 minutes (Standardsetting)ParameterP73.13 RADIATORS ANTI-FREEZEFUNCTION.If the system return water is below 4°C, the boilerstarts up until reaching 42°C.21 - IE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!