11.07.2015 Views

EOLO STAR 24 3 E - E-servisas

EOLO STAR 24 3 E - E-servisas

EOLO STAR 24 3 E - E-servisas

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTALLATOR3.17 VARIABLE HEAT POWER.N.B.: the pressures indicated in the table representthe difference in existing pressures betweenthe gas valve outlet and the combustion chamber.The adjustments should therefore, be carriedout using a differential manometer (small “U”-shaped column or digital manometer) with theprobes inserted in the pressure test gas valveoutlet and on the sealed chamber positive pressuretest. The power data in the table has beenobtained with intake-exhaust pipe measuring 0.5m in length. Gas flow rates refer to heating powerbelow a temperature of 15°C and at a pressure of1013 mbar. Burner pressure values refer to useof gas at 15°C.METHANE (G20) BUTANE (G30) PROPANE (G31)USERTECHNICIANHEATINGPOWERBURNERGAS FLOWRATEPRESS. BURNERNOZZLESBURNERGAS FLOWRATEPRESS. BURNERNOZZLESBURNERGAS FLOWRATEPRESS. BURNERNOZZLES(kW) (kcal/h) (m 3 /h) (mbar) (mm H 2O) (kg/h) (mbar) (mm H 2O) (kg/h) (mbar) (mm H 2O)23,8 20468 H 2,70 11,40 116,3 2,01 28,20 287,6 1,98 36,30 370,223,0 19780E2,61 10,65 108,6 1,94 26,30 268,2 1,91 33,97 346,4A21,9 18806 T 2,48 9,65 98,4 1,85 23,76 <strong>24</strong>2,3 1,82 30,84 314,521,0 18060 I 2,38 8,92 91,0 1,78 21,93 223,6 1,75 28,58 291,520,0 17200N2,27 8,13 82,9 1,70 19,94 203,3 1,67 26,11 266,2G19,0 16340 2,16 7,39 75,3 1,61 18,07 184,3 1,59 23,77 <strong>24</strong>2,418,0 15480 + 2,06 6,69 68,2 1,53 16,31 166,3 1,51 21,56 219,817,0 14620 1,95 6,02 61,4 1,45 14,65 149,4 1,43 19,46 198,5DOME-16,0 13760 STIC 1,84 5,40 55,1 1,37 13,10 133,6 1,35 17,48 178,315,014,01290012040HOTWATER.1,741,634,8<strong>24</strong>,2749,143,51,301,2211,6510,28118,8104,91,271,2015,6113,85159,2141,213,0 11180 1,52 3,75 38,3 1,14 9,01 91,9 1,12 12,18 1<strong>24</strong>,312,0 10320 1,42 3,27 33,4 1,06 7,83 79,9 1,04 10,62 108,311,5 9847 1,36 3,03 30,9 1,01 7,<strong>24</strong> 73,8 1,00 9,82 100,210,0 86001,19 2,36 <strong>24</strong>,1 0,89 5,62 57,3 0,87 7,62 77,79,0 7740 DOME- 1,07 1,95 19,9 0,80 4,64 47,3 0,78 6,25 63,78,0 6880STICHOT0,95 1,59 16,3 0,71 3,79 38,6 0,70 5,02 51,27,0 6020 WATER. 0,83 1,27 13,0 0,62 3,04 31,0 0,61 3,91 39,96,8 5848 0,81 1,22 12,4 0,60 2,91 29,7 0,59 3,71 37,83.18 COMBUSTION PARAMETERS.G20 G30 G31Gas nozzle diameter mm 1,35 0,79 0,79supply pressure mbar (mm H 2O) 20 (204) 29 (296) 37 (377)Mass flow of fumes at nominal power kg/h 53 53 55Mass flow of fumes at min. power kg/h 52 53 54CO 2at Q. Nom./Min. % 6,95 / 1,95 8,00 / 2,<strong>24</strong> 7,66 / 2,20CO at 0% di O 2at Q. Nom./Min. ppm 79 / 140 95 / 147 63 / 137NO Xat 0% di O 2at Q. Nom./Min. ppm 55 / 34 77 / 30 78 / 30Temperature of fumes at nominal output °C 110 112 109Temperature of fumes at minimum output °C 96 93 95<strong>24</strong> - IE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!