<strong>Crime</strong> & Criminals Tracking Network and Systems ProjectHaryana Police13. LED indica<strong>to</strong>rs should be provided for at least load indication, load on battery,low battery, overload, Mains ON.14. Galvanic Isolation <strong>to</strong> be provided through inbuilt double wound transformer a<strong>to</strong>utput15. Audible indica<strong>to</strong>r should be provided for at least load on battery, low battery,Mains failure, Overload4. 2 KVA or 5 KVA Genera<strong>to</strong>r Set2KVA Genera<strong>to</strong>r Set - all Police Units/ OfficesMinimum Technical Specifications for DG Set1. The proposed DG set should be able <strong>to</strong> support the Police Unit equipmentsalong with AC, in absence of primary power source.Engine shall be vertical multi cylinder 4 stroke type in accordance with IS10002-1981 with latest amendments.TypeMulti cylinderMethod of startingElectric start 12 V DCType of coolingWater cooled /Air cooledType of governorMechanical/ElectronicType of fuelHigh speed dieselRatingContinuousOutput Suitable HP rated <strong>to</strong> match thealterna<strong>to</strong>rRated speedOver load capacity1500 RPM10% overload – minimum 1 hour50% overload – minimum 1 minute2. AccessoriesFlywheel <strong>to</strong> suitable diameter and fuel injection equipmentAir cleanerLubricating oil coolerElectric mo<strong>to</strong>r starting equipment like mo<strong>to</strong>r, battery, charginggenera<strong>to</strong>r with voltage regula<strong>to</strong>r etc.Heavy duty radia<strong>to</strong>r with fanResidential type silencer with exhaust piping with vibration isola<strong>to</strong>rFuel tank suitable for 8 Hrs of continuous running with necessarypiping and fuel gauge, drain valve, inlet and outlet connections.Anti vibration mounting pads (Dunlop)Speed controlling governorSuitable coupling system <strong>to</strong> the Alterna<strong>to</strong>rTachometerLubricating oil pressure gaugeHour meter <strong>to</strong> indicate number of Hrs of operationAu<strong>to</strong> trip on low oil pressureOver speed alarm with tripThermal insulation for exhaust line with glass wool, Aluminiumsheet, chicken mesh, Diesel line 12 mm dia including beadsflangeretcBattery 12 V with lead and terminalBattery charger.Protection: Protection against low lubricating oil pressure, highwater temperature and over speed shall be provided for engine withalarm and fuel shut off.Government of Haryana <strong>Corrigendum</strong> <strong>to</strong> <strong>RFP</strong> for Selection of System Integra<strong>to</strong>r Page 41 of 61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!