12.07.2015 Views

DayandNight MV Blower Specs.pdf

DayandNight MV Blower Specs.pdf

DayandNight MV Blower Specs.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MODULAR BLOWER: <strong>MV</strong>INSTALLATION INSTRUCTIONSTable 4ModularUnit Size<strong>MV</strong>08<strong>MV</strong>12<strong>MV</strong>16<strong>MV</strong>20Modular Airflow Delivery (CFM) in Cooling Mode (either A/C or HP)Single--Stage A/CTwo--Stage CoolingOutdoorFan OnlyCooling A/C Cooling -- High A/C Cooling -- LowUnit SizeNominal Dehum Nominal Dehum Nominal Dehum LOW MED HI18 525 420 -- -- -- -- -- -- -- -- 350 420 52524 700 560 700 560 560 450 350 560 70030 875 700 -- -- -- -- -- -- -- -- 440 700 87536 1050 840 1050 840 840 670 525 840 105024 700 560 700 560 560 450 415 560 70030 875 700 -- -- -- -- -- -- -- -- 440 700 87536 1050 840 1050 840 840 670 525 840 105042 1225 980 -- -- -- -- -- -- -- -- 615 980 122530 875 700 -- -- -- -- -- -- -- -- 440 700 87536 1050 840 1050 840 840 670 525 840 105042 1225 980 -- -- -- -- -- -- -- -- 615 980 122548 1400 1120 1400 1120 1120 900 700 1120 140036 1050 840 1050 840 840 670 540 840 105042 1225 980 -- -- -- -- -- -- -- -- 615 980 122548 1400 1120 1400 1120 1120 900 700 1120 140060 1750 1400 1750 1400 1400 1120 875 1400 1750NOTES:1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM.2. Airflow can be adjusted +15% or --10% by selecting Hi or Lo respectively for all modes except fan only.3. Dry coil at 230 volts and with 10kW heater and filter installed.4. Airflows shown are valid for systems with total static pressure between 0.1 and 0.7 in wc.Table 5ModularUnit Size<strong>MV</strong>08<strong>MV</strong>12<strong>MV</strong>16<strong>MV</strong>20Modular Airflow Delivery (CFM) in Heat Pump Heating Mode OnlySingle--Stage HPTwo--Stage HeatingOutdoorFan OnlyHeatingHP Heating -- High HP Heating -- LowUnit SizeComfort Eff Comfort Eff Comfort Eff Low Med Hi18 475 525 -- -- -- -- -- -- -- -- 350 380 47524 630 700 630 700 505 560 350 505 63030 785 875 -- -- -- -- -- -- -- -- 440 630 78536 945 1050 945 1050 755 840 525 755 94524 630 700 630 700 505 560 415 505 63030 785 875 -- -- -- -- -- -- -- -- 440 630 78536 945 1050 945 1050 755 840 525 755 94542 1100 1225 -- -- -- -- -- -- -- -- 615 880 110030 785 875 -- -- -- -- -- -- -- -- 440 630 78536 945 1050 945 1050 755 840 525 755 94542 1100 1225 -- -- -- -- -- -- -- -- 615 880 110048 1260 1400 1260 1400 1010 1120 700 1010 126036 945 1050 945 1050 755 840 540 755 94542 1100 1225 -- -- -- -- -- -- -- -- 615 880 110048 1260 1400 1260 1400 1010 1120 700 1010 126060 1575 1750 1575 1750 1260 1400 875 1260 1575NOTES:1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM.2. Airflow can be adjusted +15% or --10% by selecting Hi or Lo respectively for all modes except fan only.3. Dry coil at 230 volts and with 10kW heater and filter installed.4. Airflows shown are valid for systems with total static pressure between 0.1 and 0.7 in wc.Table 6Airflow Adjust TableTable 7Outdoor Unit SizeMODEL # AUX HEAT RANGE (KW/CFM)MODEL #OUTDOOR UNIT SIZE (BTU)VIOLETWire A B C DSelection<strong>MV</strong>08 15kw -- -- 10kw 5thru7.5kw<strong>MV</strong>12 -- -- 15 thru 20kw 10kw 5thru7.5kw<strong>MV</strong>16 -- -- 25kw -- -- 5 thru 20kw<strong>MV</strong>20 -- -- -- -- 25kw 5 thru 20kwBLUE WireSelectionA B C D<strong>MV</strong>08 036 030 024 018<strong>MV</strong>12 042 036 030 024<strong>MV</strong>16 048 042 036 030<strong>MV</strong>20 060 048 042 036442 01 2305 0110

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!