<strong>Maintenance</strong>Below is the complete listing offailure indication causes:System failureCheck the voltage betweenterminals 6 and 9 on J6, it shouldread approximately 32 VDC. If novoltage is present, a system failurehas occurred. Refer to Step 4 in theprevious section for therecommended troubleshootingprocedure.Heating FailureVerify Heat Failure by IgnitionModule (IGN) LED indicator:OFF: No Power or FailureON: NormalSlow Flash: Normal, Heat CallFast Flash: Error Code:1 Flash: Communication Failure2 Flashes: System Lockout3 Flashes: Pressure Switch Fail4 Flashes TC01 or TC02 Open5 Flashes: Flame w/o Gas Valve6 Flashes: Flame Rollout OpenCooling Failure1. Cooling and heating set point(slide pot) on the zone sensorhas failed. Refer to the "ZoneSensor Test Procedure" section.2. Zone temperature thermistorZTEMP on ZTS failed. Refer tothe "Zone Sensor Test Procedure"section.3. CC1 or CC2 24 VAC control circuithas opened, check CC1 & CC2coils, and any of the controlsbelow that apply to the unit(HPC1, HPC2).4. LPC1 has opened during the3 minute minimum "on time"during 4 consecutive compressorstarts, check LPC1 or LPC2 bytesting voltage between the J1-8& J3-2 terminals on the RTRMand ground. If 24 VAC is present,the LPC's has not tripped. If novoltage is present, LPC's hastripped.Service Failure1. If the supply fan proving switchhas closed, the unit will notoperate (when connected toRTOM), check the fan motor,belts, and proving switch.2. Clogged filter switch has closed,check the filters.Simultaneous Heat and Cool Failure1. Emergency Stop is activatedMethod 2The second method for determiningsystem status is done by checkingvoltage readings at the RTRM (J6).The system indication descriptionsand the approximate voltages arelisted below.System FailureMeasure the voltage betweenterminals J6-9 & J6-6.Normal <strong>Operation</strong> = approximately32 VDCSystem Failure = less than 1 VDC,approximately 0.75 VDCTest Mode = voltage alternatesbetween 32 VDC & 0.75 VDCHeat FailureMeasure the voltage betweenterminals J6-7 & J6-6.Heat Operating = approximately32 VDCHeat Off = less than 1 VDC,approximately 0.75 VDCHeating Failure = voltage alternatesbetween 32 VDC & 0.75 VDCCool FailureMeasure the voltage betweenterminals J6-8 & J6-6.Cool Operating = approximately32 VDCCool Off = less than 1 VDC,approximately 0.75 VDCCooling Failure = voltage alternatesbetween 32 VDC & 0.75 VDCRT-SVX20B-E463

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!