Appendix A: Energy Analysis <strong>for</strong> Premier Gardens<br />

Comparison of Total Energy Use<br />

Plan 2248 and Options<br />

Title 24 Code House<br />

ZEH: Tankless WH,<br />

Fluorescent lighting, 2.4kW<br />

DC PV, Inspections and<br />

Diagnostics<br />

Energy Use Dollars Energy Use Dollars<br />

Therms kWh $ Therms kWh $<br />

Energy Code Related<br />

Space Heating 387 $290.50 267 $200.13<br />

Space Cooling 2158 $179.58 891 $ 74.17<br />

Water Heating 239 $179.39 164 $122.74<br />

O<strong>the</strong>r Uses<br />

cooking 44 $ 33.00 44 $ 33.00<br />

microwave 209 $ 17.39<br />

209 $ 17.39<br />

dishwasher 361 $ 30.04<br />

361 $ 30.04<br />

cloths dryer 700 $ 58.25 35 $ 26.25<br />

refrigerator 1100 $ 91.53<br />

1100 $ 91.53<br />

Miscellaneous 1800 $149.78 1088 $ 90.55<br />

reduce kWh by solar contribution n/a -3,420 $284.58<br />

Total use 671 6328 $1,029.46 509 230 $401.23<br />

100% 96.37% 61%<br />

price of gas/<strong>the</strong>rm $ 1.00<br />

price of electricity/kWh $ 0.11<br />

Table 2 : Comparison of Total Energy Use<br />

1<br />

1067 $ 85.79 /mo $ 33.44 /mo