12.07.2015 Views

Phys 1 Student Workbook.pdf

Phys 1 Student Workbook.pdf

Phys 1 Student Workbook.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Phys</strong>ics Labs with Computers, Vol. 1<strong>Student</strong> <strong>Workbook</strong>P24: Conservation of Linear and Angular Momentum 012-07000AFor You To DoUse the Projectile Launcher to shoot the ball into the Projectile Catcher mounted on the RotatingPlatform. Use the Photogate/Pulley System to measure the motion of the Rotating Platform afterthe ball is captured. Use DataStudio or ScienceWorkshop to obtain the angular velocity of thesystem. From the data, calculate the average initial linear velocity of the ball.PART I: Computer Setup1. Leave the Photogate’s phone plug connected to Digital Channel1 on the interface.2. Open the document titled as shown:500 scientificPASCOInterfacescientific 300PASCOANALOG CHANNELSScienceW orkshop DATA LOGGING INSTRUCTIONSScienceWorkshopInterfaceDataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win)P24 Linear Angular.DS P28 Cons Linear & Ang Mom P28_CLAM.SWS• The DataStudio document has a <strong>Workbook</strong> display. Read the instructions in the <strong>Workbook</strong>.• The ScienceWorkshop document has a Table display of angular velocity.PART II: Sensor Calibration and Equipment Setup• You do not need to calibrate the Photogate/Pulley System.1. Measure the distance from the axis of the Rotating Platform to the center of the ball in theCatcher. Record the distance as the radius, R, in the Data section.2. Remove the ball from the Projectile Catcher. Measure the mass of the ball, mb, and recordthe value in the Data section.3. Remove the Photogate/Pulley System from the Rotating Platform’s supportpost and also remove the support post. Remove the pulley so you can use thePhotogate. Remove the swivel clamp from the side of the Photogate.4. Attach the Photogate to the Rotating Platform’s short threaded rod. Mount thePhotogate to the base of the Rotating Platform.5. Adjust the position of the threaded rod so the Photogate is aligned with theholes on the bottom lip of the Rotating Platform’s step pulley.® PHOTOGATE HEADASSEMBLY NO.003-06268® PHOTOGATE HEADASSEMBLY NO.003-06268p. 174 ©1999 PASCO scientific P24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!