EOS0615i-DUO3 LAYOUT and OPERATION FLOW CHARTS (v3.1 firmware version)EOS0615i-DUO3 CHARGER LAYOUTDC INPUT CABLE11V~28V2X16 LCDYellow BacklitPC DATAUSB PORTTEMP1SENSOROUTPUTPORT CH#1UPOUTPUTPORT CH#2TEMP2SENSORMODEENTERCHDOWNCH #1 1~6 CellLithium BalancerConnectorCH #2 1~6 CellLithium BalancerConnector


(1) MAIN MENU FLOWHYPERION RC0615iiDUO3 x.xMEMORY 1DISPLAYENTER-2SECDATA VIEW 1BALANCER INFOR1DISPLAYDISPLAYMODE MODE MODEENTER-2SECUSER SETUP 1DISPLAYMODEOperation Start 1DISPLAYBalancer Start 1DISPLAYCharge Operation 1DISPLAYBalancer Operation 1DISPLAYCHMEMORY 2DISPLAYENTER-2SECDATA VIEW 2BALANCER INFO 2DISPLAYDISPLAYMODE MODE MODEENTER-2SECUSER SETUP 2DISPLAYMODEOperation Start 2DISPLAYBalancer Start 2DISPLAYCharge Operation 2DISPLAYBalancer Operation 2DISPLAY


(2) MEMORY DISPLAY (settings available per each memory slot, depending on battery type)LiIo/LiPo/LiFePO4 (a123) NiCd/NiMH Pb[ MEMORY No.0 ] 1A123 9.9V 2300 ENTERDOWNUPBATT TYPE 1A123ENTERDOWNUPBATT VOLTS 19.9Vpack ( 3S)ENTERDOWNUPBATT CAPACITY 12300mAhENTERDOWNUPCHG CURRENT15.0AENTERDOWNUPTEMPERATURE 1CUT-OFF 00`CENTERDOWNUPSAFETY TIMER 1000MINENTERDOWNUPTCS CAPACITY 1100%ENTERDOWNUPTCS END ACTION 1<strong>CONT</strong>INUEENTERDOWNUPDSCH CURRENT 11.0AENTERDOWNUPDSCH VOLTAGE 13.0V / CELLENTERENTERENTERENTERENTERENTERENTERENTERENTERTCS CAPACITY 1100%ENTER DSCH CURRENT 11.0AENTER[ MEMORY No.0 ] 1A123 9.9V 2300BATT TYPE 1A123BATT VOLTS 19.9Vpack ( 3S)BATT CAPACITY 12300mAhCHG CURRENT 115.0ATEMPERATURE 1CUT-OFF 00`CSAFETY TIMER 1000MINENTER TCS END ACTION 1<strong>CONT</strong>INUEDSCH VOLTAGE 13.0V / CELLUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWNUPDOWN[ MEMORY No.0 ] 1NiMh 7.2V 1800BATT TYPE 1NiMhBATT VOLTS 17.2Vpack ( 6S)BATT CAPACITY 11800mAhCHG CURRENT 11.8APEAK SENS. 13mV/CTRICKLE 10mAPEAK DELAY 13minTEMPERATURE 1CUT-OFF 50`CSAFETY TIMER 1300MINCHG CAPACITY 1LIMITED 100%DSCH CURRENT 11.0ADSCH VOLTAGE 10.8V / CELL[ MEMORY No.0 ] 1Pb 12.0V 40.0BATT TYPE 1PbBATT VOLTS 112Vpack ( 6S)BATT CAPACITY 140.0AhCHG CURRENT 17.0ATEMPERATURE 1CUT-OFF 50`CSAFETY TIMER 1300MINDSCH CURRENT 11.0ADSCH VOLTAGE 11.8V / CELL


(3) DATA VIEW DISPLAY (4) BALANCE INFORMATION DISPLAY[ DATA VIEW ] 1INPUT 00.000VUPDOWNOUTPUT 00.000V 1BAT. RES 000mΩUPDOWNTEMP 000.0`C 1PEAK.T 000.0`CUPDOWNCHG TIME 1000min 00secUPCHG C. 00000mAh 1PEAK.V 00.000VUPUPUPDOWNDOWNDCHG TIME 1000min 00secDOWNDCHG 00000mAh 1AVR.V 00.000VDOWNCYC C: 000000mAh 10] D: 000000mAh[ BALANCER ] 10CL 0.000V 0%UPDOWNSELECT [0CL] 1VOLTAGE 00.000VUPDOWNAVG. V 00.000V 1GAP V 00.000VUPDOWN0.00 0.00 0.00V 10.00 0.00 0.00VENTER-2SECThe 0% under [ BALANCER ]above indicates TCS% (capacity)BALANCE START 1SOLO MODEENTER-2SEC* * BATTERY * ** * CHECK * *CONNECTED CELLS 1[0CELLS] 00.0VENTERBalancer OperationDISPLAYENTERUPDOWNBALANCE START 1SYNC MODEENTER-2SEC* * BATTERY * ** * CHECK * *[0CELLS] 00.0V 1[0CELLS] 00.0V 2ENTERBalancer OperationDISPLAY10-second AUTO Countdown. Starts charge after 10seconds if user does not confirm cell count, onlyduring Balance/Charge for Li~ types.


(5) USER SETUP DISPLAYCH#1 Global Settings CH#2 Global Settings[USER SETUP] 1TEMP MODE `CENTERDOWNUPBUTTON SOUND 1ONENTERDOWNUPFINISH SOUND 1TIME 5secENTERDOWNENTERENTERENTER[USER SETUP] 1TEMP MODE `CBUTTON SOUND 1ONFINISH SOUND 1TIME 5secUPDOWNUPDOWNUPDOWN[USER SETUP] 2TEMP MODE `CBUTTON SOUND 2ONFINISH SOUND 2TIME 5secFINISH SOUND 2MELODY 1[USER SETUP] 2TEMP MODE `CBUTTON SOUND 2ONFINISH SOUND 2TIME 5secFINISH SOUND 2MELODY 1UPFINISH SOUND 1MELODY 1ENTERDOWNENTERFINISH SOUND 1MELODY 1UPDOWNUPLIPO MAX C 12CENTERDOWNENTER LIPO MAX C 12CUPDOWNLipo “Max C” is set to 2C by default. Select 1C to 5C as desired.UPPOWER SUPPLY 1VOLTAGE 00.0VDOWNENTERENTERPOWER SUPPLY 1VOLTAGE 00.0VUPDOWNUPPOWER SUPPLY 1CURRENT 00.0AENTERDOWNENTERPOWER SUPPLY 1CURRENT 00.0AUPDOWNUP2POWER SHARING 100% - - - - - - - - - - 00%The PS Load Control settings above and LIPO MAX C are only found under CH#1 menu, but are effective for all memory positions on both channels.


(7) LiIo / LiPo / A123 BATTERY START (8) PB BATTERY START[ MEMORY No.0 ] 1A123 9.9V 2300ENTER-2SECSelection of “No Balancer” Vs. “Solo Mode” is automatic,depending on connection (or not) to balance port.[ MEM ORY No.0 ]Pb 12.0V 45000ENTER-2SECMODEMODECHARGE START 1NO BALANCERDOWNCHARGE START 1SOLO MODEDOWNENTERUPDOWNCHARGE START 1SYNC MODECHARGE START 1CC/CVDOWNUPSTORE START 1NO BALANCERDOWNUPSTORE START 1SOLO MODEDOWNENTERUPDOWNSTORE START 1SYNC MODEUPDISCHARGE START 1LINEARUPDISCHARGE START 1NO BALANCERUPDISCHARGE START 1SOLO MODEENTERUPDOWNDISCHARGE START 1SYNC MODEENTER-2SECENTER-2SECENTER-2SECENTER-2SEC* * BATTERY * *** CHECK *** * BATTERY * ** * CHECK * ** * BATTERY * ** * CHECK * ** * BATTERY * ** * CHECK * *SELECT CELLS 1[0CELLS] 00.0VCONNECTED CELLS 1[ 0CELLS] 00.0V[0CELLS] 00.0V 1[0CELLS] 00.0V 2ENTERENTERENTEROPERATION 1DISPLAYOPERATION 1DISPLAYOPERATION 1DISPLAYOPERATION 1DISPLAYNote: STORE Mode only applies to LiIo, LiPo, and LiFePO4(a123) types. Balancer Connection is required. If Balancer is NOT connected OUTPUT BATTERY CONNECT ERROR


(9) OPERATION and FINISH DISPLAY[SOLO-RUNNING] -> SOLO mode balance[SYNC-RUNNING] -> SYNC mode balance[ **COMPLETE** ] -> Balance completeConnected cell numberConnected Pack voltageConnected Pack TCSSelected cell numbercell voltageMODE[ BALANCER ] 16CL 00.000V 0%DOWNLiIo -> Lithium-ion batteryLiPo -> Lithium polymer batteryA123 -> Lithium Fe batteryMODE C 0000mAh 00.0Vi 100.00V 00.00A 00%MODEAUTO : AUTOMATICNORM : NORMALLINE: LINEARSOLO : SOLO MODESYNC : SYNC MODECcCv: CC-CVC01D : CYCLE MODESTOR : STORE MODEA123 SYNC 000:00 100.00A 0.000VUPA123 CHG 000:00 100.00A 0.000VDOWNENTERIf LONG UP button is pressed, eachparameter will display in 2-second rotation.Output currentOutput voltageENTER A123 CHG 000:00 100.00A 0.000VUPDOWNUPSELECT [0CL] 1VOLTAGE 00.000VDOWNUPAVG. V 00.000V 1GAP V 00.000VDOWNUP3 68 3.62 3.63V 13.62 3 70 3.62VQUICK VIEW DATA DISPLAYC : Charge or D : DischargemAh (charged in or discharged out)Vi Input (i) VoltageV Pack Voltage,A Charge Current% TCS capacity (Lithium types only.NiCd, NiMH, PB show --%)00.00A 0.000VCAPA. 00000mAhINPUT 00.000VTEMP 0.0`CPEAK.T 0.0`CPEAK.V 0.000VBAT. RES 000mΩTCS CAP. 000%FINISH…Capacity Units DisplayedNiMh, NiCd, LiPo, Liio, LiFePO4 = mAhPb = AhOutput current, Output voltageCharge capacityInput voltageBattery temperatureBattery peak temperatureBattery peak voltageBattery internal resistanceTCS capacityThe decimal point changes to squarebox to indicate a high cell which isbeing discharged to balanceA123 CHG 000:00 100.00A 0.000VCOMPLETE 100.00A 0.000VFinish status display"END:DELTA-PEAK ""COMPLETE"“END:CUTOFF-VOLT”"END:TEMPERATURE""END:CAPACITY ""END:TIMER ""END:TCS CAP. "[ MEMORY No.0 ] 1A123 9.9V 2300ENTER-2SEC


(10) LiIo / LiPo / LiFePO4 (a123) FINISH DISPLAYLiPo CHG 62:24 1+ 1.00A 8.103VLiPo SOLO 62:25 1+ 1.00A 8.103VCharge CC/CV & DischargeOperating DisplayLiPo CHG 65:32 1 LiPo BLC 65:32 1+ 1.00A 8.103V + 0.20A 8.103VClock continues to count time until BLC is finishedCurrent (if any) during BLC is shownLiPo CHG 68:40 1+ 0.00A 8.400VLiPo END 68:40 1+ 0.00A 8.400VEND time should show total of CC/CV and BLCphases(11) NiCd/NiMH CYCLE OPERATION DISPLAY[ MEMORY No.0 ]NiMh 7.2V 3300ENTERCYCLE STARTC>D 5T 10minENTER* * BATTERY * ** * CHECK * *NiMh C01D 00:01 1+ 4.00A 7.512VNiMh C01D 09:59 1+ 0.00A 8.720VNiMh C01D 09:59 1- 4.00A 8.713VEND:CUTOFF-VOLT 100.00A 0.000VNiMh C01D 09:59 1- 0.00A 6.618V5 Cycle repeat


ERROR MESSAGESINPUT VOLTAGEERROR 0.00ViOUTPUT BATTERYCONNECT ERROROUTPUT BATTERYREVERSE POLARITYOUTPUT BATTERYOPEN CIRCUITOUTPUT CIRCUITERROROUTPUT VOLTAGETOO LOW 0.00VOUTPUT VOLTAGETOO HIGH 0.00VTEMPERATURESENSOR ERRORBATTERY TEMPTOO LOW 0.00VBATTERY TEMPTOO HIGHINTERNAL TEMPTOO HIGHBALANCE VOLTAGECELL(0) TOO HIGHPAUSE...CHARGER TOO HOTSYNC COMMANDERRORFLAT CHECKWhen input voltage is below 11.0V or exceeds 28V.When a battery is not connected to the charger’s outputOutput battery is connected to the output in reverse polarity (switch +/-)If the battery becomes disconnected during an operationThe output circuit of the charger has a problem. See troubleshooting above.Output voltage is lower than the selected cells or voltages (check battery specs and condition, or reset charger correctly)Output voltage is higher than the selected cells or voltages.The thermal probe is incorrectly connected, or the probe is damaged.The temperature of the battery is too low ( below -10’C at idle mode and 0’C during operation, requires probe attached!).Battery temp is too high to be charged! (requires probe attached!)When the temperature of the charger exceeds 125C. Reduce room temp, wait, restart.When the balancing cell voltage is too high. Possible pack damage or connection error.Charger temperature is too high. Charger will Pause until temp dropsProblem with wiring, connectors, or other. Clean and inspect as in Troubleshooting section for OUTPUT ERRORNiCd, NiMH only. Charger cannot detect DeltaV to terminate charge. See Troubleshooting section.


CONNECTOR WIRING FOR HYPERION-COMPATIBLE PACKSDUO3 includes 2x HYPERION compatible Multi-adapters for 2S to 6S packs (#HP-EOSLBA-26HP).Other brand adapters are available as option parts, HP-EOSLBA-26xx-B as below:IF YOUR PACK MAKER IS NOT LISTED BELOW, ASK THE MAKER WHICH BRAND BELOW IT MATCHES.HP-EOSLBA-26XH-B HP-EOSLBA-26HP-B HP-EOSLBA-26TP-B HP-EOSLBA-26EH-BALIGN HYPERION THUNDER POWER KOKAMDUALSKY POLYQUEST FLIGHTPOWER-EVO GRAUPNERE-FLIGHT E-TEC APEX ROBBEELECTRIFLY POLY RC VISLERO NEUHEXTRONIC XCITE DANLIONS APOGEECOMMON SENSE V1 MAX AMPS MPX VAMPOWERCOMMON SENSE V2 TRUE RCESKY IMPULSEVENOMAIR THUNDERKONG THUNDERGRAYSON POWERTENERGYDN POWERMEGA POWERELECTRIC POWERTURBORIXENERGY EC, WOW RCIMAXFULLY MAXFUSION