<strong>VRIOGS</strong> <strong>010.3</strong> Revision A 13f) A minimum of two emergency doors shall be provided from all HighVoltage and 1500V DC areas, generally located diagonally opposite eachother and purposely located to allow ready emergency exit.g) The designated normal access into the building need only be provided withan externally accessible lock. All separate compartmented rooms shall allhave locked accessibility and emergency egress being provided by meansof panic bars fitted to locks.7.5.4 FENCINGThe substation shall be bounded by a security fence with lockable entrance gates.All external equipment including the substation building shall be enclosed in acompound (or switchyard) using a chain link fence. Fencing shall be earthed, andshall maintain clearances from equipment as specified in A.S. - 2067, or asnecessary to provide truck access to any item of equipment, whichever is greater.The fence or enclosure shall be a minimum of 3m away from the substationbuildings.One or more sets of matching gates with a minimum length of 3600mm shall allowaccess to the compound. The gates shall be equipped with heavy duty & vandalproof means of securing the substation. Robust drop bolts, locking chains andpadlock shall be provided for each gate.The fencing and gate design shall be such that the largest item of plant in thesubstation can be transported out without the need to dismantle any part the fence orgate.Where the substation is prone to vandalism a concrete panel enclosure or a palisadetype fence shall be used instead of a chain link fence.7.5.5 ALARM SYSTEMAll areas of the substation shall be covered by heat and smoke detection and analarm system. The alarm system shall be activated by quad sensors with motion andIPR activation.NOTE:This document is controlled only when viewed on the DOT Engineering Standards website.Any other copy of this document is uncontrolled, and the content may not be current.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!