Tintometer ® -GrouppH200Technical DatapH 0.00 ... 14.00Accuracy± 0.01 pH (at nominaltemperature, unit ± 1 digit)Temperature -10.0 ... +110.0 °C14.0 ... 230.0 ° FAccuracyRedox (ORP)±0.2 °C (-0..50 °C),otherwise ± 0.4 °C-1999 ... +2000 mVRelative Redox -1792 ... +2206 Rel mV(based on DIN 38 404AccuracySensorconnections± 0.1 % FS (mV or Rel mV)DIN 19262 andtwo 4 mm banana sockets"Temp” and "Ref”Input resistance >1012 Ohm (typ.)Input current15,000hPower 0.2 mAconsumptionAuto-Off function 0 - 120 minutesCalibration 1-, 2- or 3-point calibrationwith auto buffer recognitionTintometer buffer, DIN bufferor user-selectable bufferCE-ConformitySensoDirect pH200 in carrying caseDelivery ContentSensoDirect pH200CodeArticle721200 SensoDirect pH200, without electrode,with batteries, instruction manual,in case721220 SensoDirect pH200 (SET 1)instrument, batteries,pH/temp. plastic-electrode type 230,pH-buffer-set (pH 4.00/7.00/10.00),in case, manual, guarantee sheet721221 SensoDirect pH200 (SET 2)as SET1, but with pH/temp. plasticelectrodetype 225, and temperaturesensor Pt 1000, manual, guarantee sheetAccessories pH200721225 pH-electrode plastic/gel-type 225 (SET 2)721230 pH/temp.-electrode type 230plastic/gel/temperatureNTC30kOhm (SET 1)721235 pH-electrode glass/gel-type 235721240 Redox-electrode plastic-type 240721245 Temperature sensor (SET 2)418609 KCl-solution, 3 molar saturatedwith AgCl, 100 ml721250 pH buffer-set 4.00/7.00/10.00 (25°C)721252 pH buffer 4.00 (25°C) 1 litre721254 pH buffer 7.00 (25°C) 1 litre721256 pH buffer 10.00 (25°C) 1 litre721260 Adapter cable DIN19262 - BNC721265 Adapter cable DIN19262, S7 plug-head725020 Case with foam inletCon200Technical DataConductivity 0.0 ... 200.0 µS/cm0 ... 2000 µS/cm0.00 ... 20.00 mS/cm0.0 ... 200.0 mS/cmResistance 0.005 ... 100.0 kOhm*cmTDS0 ... 1999 mg/lSalinity 0.0 ... 70.0 g/kgAccuracy ± 0.5 % of result ± 0.5 % FS(± 3 digits)Temperature -5.0 ... 100.0 °C23.0 ... 212 ° FAccuracy ±0.3KCell constant 0.50 ± 0.10 cm-1Temperature selectable:compensation - linear , 0.3 to 3.0 %/K- non-linearin acc. with EN 27 888- no compensationReference 20 °C and 25 °CtemperatureCalibration 1-point calibration in the rangefrom 1000 to 2000 µS/cmNominal 25 °CtemperatureOperating Unit: 0 to + 50 °Ctemperature Measuring cell: -5 to 80 °C(up to 100 °C for short periods)Power supply 4 x 1.5 V battery, Type AAOperating time up to 1500 hPower ca. 2 mA, max. 4.2 mAconsumptionAuto-Off 0 - 120 minutesfunctionMeasuring cell 4-pole conductivitymeasuring cell withintegrated temperaturesensor(NTC10kOhm).Electrode material:special graphiteShaft material: epoxyTemperature sensor:stainless steelDimensions:diameter 12 mm, 120 mm longCE-Conformity114 Regularly updated information: www.lovibond.com <strong>General</strong> <strong>Catalogue</strong> November 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!