12.07.2015 Views

General Catalogue

General Catalogue

General Catalogue

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MD 100MD 100MD 100 2in1TestCodeTestCodeTestCodeAmmonia, tablet reagents 27 60 600.02 - 1.0 mg/l NAmmonium, powder reagents 27 60 650.01 - 0.8 mg/l NAmmonia, free powder reagents 27 60 700.01 - 0.5 mg/l NMonochloramine0.04 - 4.5 mg/l Cl 2Chlorine, tablet reagents (OTZ) 27 60 00*0.01 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 2alternatively with liquid reagents0.02 - 4 mg/l Cl 2Chlorine DUO, for 2 types of reagents1) Tablet reagents 27 60 20*0.01 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 22) Powder reagents 27 60 250.02 - 2.0 mg/l Cl 2 (ø 24 mm glass vial)0.1 - 8.0 mg/l Cl 2 (ø 10 mm multi vial-2)Chlorine, powder reagents 27 60 100.02 - 2.0 mg/l Cl 2 (ø 24 mm glass vial)0.1 - 8.0 mg/l Cl 2 (ø 10 mm multi vial-2)Chlorine dioxide, tablet reagents 27 60 300.02 - 11 mg/l ClO 2Chlorine dioxide, powder reagents 27 60 350.02 - 3.8 mg/l ClO 2COD, tube tests 27 61 200 - 150 mg/l O 2 (ø 16 mm)0 - 1500 mg/l O 2 (ø 16 mm)0 - 15000 mg/l O 2 (ø 16 mm)Iron, tablet reagents 27 60 500.02 - 1.0 mg/l FeThe MD 100 uses high quality interference filterswith long-life LEDs as a light source without anymoving parts in a transparency sample chamber.The units supply accurate, reproducible resultsvery quickly. Other major advantages include easeof operation, ergonomic design, compact dimensionsand safe handling.The calibration and software-based adjustmentoptions mean that the MD 100 is also suitable foruse as a testing instrument.The tests are conducted using either Lovibond ®tablet reagents with long-term stability and aguaranteed minimum 5 or 10 year shelf life,VARIO powder reagents or using liquid reagents.Iron TPTZ, powder reagents 27 60 550.02 - 1.8 mg/l FeIron, powder reagents 27 60 560.02 - 3.0 mg/l FeFluoride, without reagents 27 60 900.05 - 2.0 mg/l F –Copper, tablet reagents 27 60 800.05 - 5.0 mg/l CuCopper, powder reagents 27 60 850.05 - 5.0 mg/l CuManganese LR, tablet reagents 27 61 000.2 - 4.0 mg/l MnManganese LR, powder reagents 27 61 050.01 - 0.7 mg/l MnManganese HR, powder reagents 27 61 060.1 - 18 mg/l MnMonochloramine powder reagents 27 60 700.04 - 4.5 mg/l Cl 2Phosphate, tablet reagents 27 60 400.05 - 4.0 mg/l PO 4Phosphate, powder reagents 27 60 450.06 - 2.5 mg/l PO 4Silica, tablet reagents 27 61 100.05 - 4.0 mg/l SiO 2Silica LR, powder reagents 27 61 150.1 - 1.6 mg/l SiO 2Silica HR, powder reagents 27 61 161 - 90 mg/l SiO 2Zero Setting (OTZ)For certain versions of the instrument it is notnecessary to zero the instrument each time. Thezero setting is held in memory until the device isturned off. (One Time Zero - OTZ). The zerosetting can be confirmed whenever it is usefull.➲ Please see pages 76 onwards fortests, ranges and reagentsChlorine, pH, tablet reagents (OTZ) 27 80 20*0.01 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 26.5 - 8.4 pHChlorine, pH, 27 80 30powder reagents for chlorine0.02 - 2.0 mg/l Cl 2 (ø 24 mm glass vial)0.1 - 8.0 mg/l Cl 2 (ø 10 mm multi vial-2)6.5 - 8.4 pHMD 100 3in1Chlorine, pH, Cyanuric acid 27 80 10tablet reagents (OTZ)0.01 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 2*6.5 - 8.4 pH ; 0 - 160 mg/l Cyanuric acidChlorine, pH, Alkalinity-M 27 80 60tablet reagents (OTZ)*0.01 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 26.5 - 8.4 pH ; 5 - 200 mg/l CaCO 3Chlorine LR, Chlorine HR, 27 80 00Chlorine dioxide, tablet reagents0.01 - 6.0 mg/l Cl 25 - 200 mg/l Cl 2 (ø 16 mm round vial)0.05 - 11 mg/l ClO 2MD 100 4in1Chlorine, pH, Cyanuric acid, 27 80 70Alkalinity-Mtablet reagents (OTZ)*0.02 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 26.5 - 8.4 pH ; 0 - 160 mg/l Cyanursäure5 - 200 mg/l CaCO 3MD 100 5in1Chlorine, pH, Cyanuric acid, 27 80 80Alkalinity-M, Calcium hardnesstablet reagents (OTZ)*0.02 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 26.5 - 8.4 pH ; 0 - 160 mg/l Cyanursäure5 - 200 mg/l CaCO 3 ; 0 - 500 mg/l CaCO 3 (CaH)MD 100 6in1Chlorine, Bromine, pH, 27 80 90Cyanuric acid, Alkalinity-M,Calcium hardnesstablet reagents (OTZ)*0.02 - 6.0 mg/l Cl 2 / 0,1 - 10 mg/l Cl 20.05 - 13 mg/l Br ; 6.5 - 8.4 pH0 - 160 mg/l Cyanursäure ; 5 - 200 mg/l CaCO 30 - 500 mg/l CaCO 3 (CaH)PhotometriePhotometryScroll Memory (SM)ApplicationsTo avoid unnecessary scrolling for the required testmethod, the instrument memorizes the last methodused before switching off the instrument. When theinstrument is switched on again, the scroll list comesup with the last used test method first.■ Water Treatment■ Waste/Drinking Water■ Cooling/Boiler Water■ Pool-Water■ Beverage Industry* Delivery without reagentsfor measuring range 0.1 - 10 mg/l Cl 2■ Laboratory andField Testing<strong>General</strong> <strong>Catalogue</strong> November 201051

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!