12.07.2015 Views

General Catalogue

General Catalogue

General Catalogue

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Tintometer ® -GroupPhotometerManufacturers Test Certificate MBesides the “Certificate of Compliance” whichis supplied with the MD 100, manufacturers testcertificates M are available at cost on request.Manufacturers test certificates M are individuallysupplied per instrument and per method.The manufacturers test certificate M has to beordered together with the new instrument andcannot be delivered at a later stage.N.I.S.T TraceabilityThe instrument has a factory calibration, whichis related to international standards which arenot N.I.S.T traceable. The instrument may becalibrated by the user in a "user calibrationmode" with N.I.S.T traceable standards.(N.I.S.T. = National Institute of Standards and Technology)Delivery Content■ Instrument in carrying case■ 4 micro batteries (AAA)■ Round vials with lids■ Tablet reagents and/orliquid reagents orVARIO Powder reagent■ Guarantee sheet■ Certificate (COC)■ Instruction ManualYou can find updated information onparameters and measuring ranges on ourwebsite at www.lovibond.comTechnical DataOpticsWavelengthAccuracyPhotometricAccuracy 4)PhotometricResolutionPower SupplyAuto - OFFDisplayStorageInterfacesAdditionalfeatureCalibrationLEDs, interference filters (IF) andphoto sensor in transparentsample chamber. Dependingon the version, up to 3 differentinterference filters are used.Wavelength specifications ofinterference filters:430 nm ∆ λ = 5 nm530 nm ∆ λ = 5 nm560 nm ∆ λ = 5 nm580 nm ∆ λ = 5 nm610 nm ∆ λ = 6 nm660 nm ∆ λ = 5 nm± 1 nm3% FS (T = 20°C – 25°C)0.01 A4 micro batteries (AAA),capacity approx. 17 hoursor 5000 testsautomatic switch-offbacklit LCD (on keypress)internal ring memory for16 data setsInfrared interface fortest data transferreal time clockand datefactory calibration anduser calibration. Reset tofactory calibration possibleDimensions 155 x 75 x 35 mm (L x W x H)Weight basic unit approx. 260 gEnvironmental Temperature: 5 – 40 °Cconditions rel. humidity: 30 – 90%(non condensing)CE-Conformity4)tested with standard solutions➲ Please see pages 76 onwards fortests, ranges and reagents52 Regularly updated information: www.lovibond.com <strong>General</strong> <strong>Catalogue</strong> November 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!