12.07.2015 Views

Mod. 006 - FIBERPOOL

Mod. 006 - FIBERPOOL

Mod. 006 - FIBERPOOL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FIBERPOOL</strong> INTERNACIONALTECHNICAL SERVICE: Ponent, 2-4-6P.I. Sant Pere Molanta, 08799 OlèrdolaBARCELONAThe control panel should be installed by an authorizedtechnician. The main power line must be protected by adifferential and a magnetothermic. The control panel will befixed to the wall by a screw in the upper part (as if it were aneyebolt), and two more screws through the holes situated inthe inside of the connection box. The control box will be placedabove the electric pump.IP 54TEMPERATURE: from 5º to 70ºCVoltage acceptable: +- 10%Feed cables and cables connecting the electric pump are to beof a 1,5mm2 wires with an insulation material of 1000v.Connections to the terminals must be made with pre-insulatedconnectors.The electric pump must be earthed. All site work to wire up thecontrol panel should be done by an authorized technician,otherwise the manufacturer guarantee will not hold.WARNING: If the equipment is used for any purpose otherthan that specified by the manufacturer, the equipmentguarantees will not hold.Every 6 months, check for tightness all the connections. Theinstallation must comply with norms of II category. The supplycables to the equipment must be installed in a way so thatsafety is maintained and the insulation is no subject to anydamage.An anchoring device such as a packing gland must beused in order to prevent twisting and traction in the cable.FUNCTIONINGRegulated current limitation control for pumps from 0,3 "A" upto a maximum of:220vII……..3HP220vIII…….4HP380vIII…….5,5HPFlexibility of uses either for single phase or three phasepumps. System is disconnected when no current is detected.The circuit has the following functions:- Magnetic (short circuit). When working at high speed, facilityof disconnection to avoid excess consumption.- RESET switch activates all the functions on the board.- The system complies with EC norms.Ponent, 2-4-6 P.I. Sant Pere Molanta08799 Olèrdola, BARCELONAMOD: P.P.A.P. 220V II7380 v III 50/60HZ CorrienteCorriente equipo: 0.3 APotencia max.: 3hp (220V II) y 5.5hp(380V III)Nº de serie: FBP-00001MAIN DIAGRAMA - MAIN SWITCHI = start light on)0 = stop (light off)A’ – SWITCHMan = ManualAut = AutomaticB - ADJUSTMENTIn order to adjust the power consumption, we will follow thetwo frontal leds (green and yellow) using the potentiometerlocated at the left hand of the connection reglet. Turn thepotentiometer in a clockwise direction to reduce the amperage.C - BREAKDOWNThe red led indicates that there is a breakdown in the system.If this ever happens, please read the paragraph "Breakdowndetection".D - RE-SETWhen a breakdown has occurred push this switch to restart thesystem.Very important: Do not use it until you have read theparagraph titled "Breakdown detection".E - TIME CLOCKPOTENTIOMETER. Necessary element to adjust electricpump amperes (situated at the left hand of the connectionreglet)A’AEDBC4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!