DIFFERENTIAL PRESSURE - Coulton Instrumentation
DIFFERENTIAL PRESSURE - Coulton Instrumentation
DIFFERENTIAL PRESSURE - Coulton Instrumentation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FKC...5Over range limit :To maximum static pressure limitOutput signal :4 to 20mA DC (linear or square root) with digital signalsuperimposed on the 4 to 20mA signalPower supply :Transmitter operates on 10.5V to 45V DC at transmitterterminals.10.5V to 32V DC for the units with optional arrester.Load limitations : see gure belowLoad resistance[]2000150010005002500Note: For communication with HHC (1) (Model: FXW), min. of 250required.Hazardous locations :Authority(Digit 10= )ATEX(K)FactoryMutual(pending)(H)CSA(J)IECEx(T)1533600Operatingarea24V45V10 16.1 50 [ V ]10.5VIntrinsic safetyEx II 1 GEx ia IIC T5 (-40°C Ta +50 °C)Ex ia IIC T4 (-40°C Ta +70 °C)IP66/67Entity Parameters:Ui 28 Vdc, Ii 94.3 mA, Pi 0.66 WCi = 36 nF/26 nF for models with/without ArresterLi = 0.7 mH/0.6 mH for models with/without Analog IndicatorClass I II IIIDiv.1 Groups A, B, C, D, E, F, GT4 Entity Type 4XModel code9th digit 13th digitTambA,B,C,D,J Y,G,N -40°C to +85°CL,P,M,1,2,3 Y,G,N -20°C to +80°CQ,S,N,4,5,6 Y,G,N -20°C to +60°CE,F,G,H,K Y,G,N -40°C to +60°C- W,A,D -10°C to +60°CEntity Parameters:Vmax=42.4V, Imax=113mA, Pi=1W,Ci=35.98nF, Li=0.694mHEx ia Class I, Groups A, B, C and D;Class II, Groups E,F and G; Class IIIPer drawing TC 522873Temp. code T5 for Tamb max = +50°CTemp. code T4 for Tamb max = +70°CEntity Parameters:Vmax = 28 Vdc, Imax = 94.3 mA, Pmax = 0.66 WCi = 36 nF/25 nF for models with/without ArresterLi = 0.7 mH/0.6 mH for models with/without Analog IndicatorEx ia IIC T5 (-40°C Ta +50 °C)Ex ia IIC T4 (-40°C Ta +70 °C)IP66/67Entity Parameters:Ui 28 Vdc, Ii 94.3 mA, Pi 0.66 WCi = 36 nF/26 nF for models with/without ArresterLi = 0.7 mH/0.6 mH for models with/without Analog IndicatorAuthority(Digit 10= )ATEX(P)FactoryMutual(pending)(H)CSA(pending)(J)IECEx(Q)AuthorityATEX(X)FactoryMutual(pending)(D)CSA(E)IECEx(R)Ex II 3 GEx nA II T5 (-40°C Ta +70 °C)IP66/67Electrical ratingsModel Without arrester:Ui 45 Vdc, 4-20 mA loop powered, Pi 1.0125 WModel With arrester:Ui 32 Vdc, 4-20 mA loop powered, Pi 1.0125 WOptional Analog indicator is not available for type "n"Class I II IIIDiv.2 Groups A, B, C, D, F, GT4 Entity Type 4XClass IDiv.2 Groups A, B, C, DClass IIDiv.2 Groups E, F, GClass IIIDiv.2Temp Code T5 Tamb max = +50°CTemp Code T4 Tamb max = +70°CEntity Parameters:Vmax = 28 Vdc, Imax = 94.3 mA, Pmax = 0.66 WCi = 36 nF/25 nF for models with/without ArresterLi = 0.7 mH/0.6 mH for models with/without Analog IndicatorEx nA II T5 (-40°C Ta +70 °C)IP66/67Electrical ratingsModel Without arrester:Ui 45 Vdc, 4-20 mA loop powered, Pi 1.0125 WModel With arrester:Ui 32 Vdc, 4-20 mA loop powered, Pi 1.0125 WOptional Analog indicator is not available for type "n"Ex II 2 GDEx d IIC T6 (-40°C Ta +65 °C)Ex d IIC T5 (-40°C Ta +85 °C)Ex tD A21 IP66/67 T 85°CEx tD A21 IP66/67 T 100°CElectrical ratingsModel Without arrester:Ui 45 Vdc, 4-20 mA loop powered, Pi 1.0125 WModel With arrester:Ui 32 Vdc, 4-20 mA loop powered, Pi 1.0125 WClass IDiv.1 Groups B, C, DT6 Type 4XClass II IIIDiv.1 Groups E, F, GT6 Type 4XTamb max = +60°CType nNonincendiveModel code9th digit 13th digitTambA,B,C,D,J Y,G,N -40°C to +85°CL,P,M,1,2,3 Y,G,N -20°C to +80°CQ,S,N,4,5,6 Y,G,N -20°C to +60°CE,F,G,H,K Y,G,N -40°C to +60°C- W,A,D -10°C to +60°CFlameproofClass I, Groups C and D;Class II, Groups E,F and G ; Class IIIMaximum ambient temperature 85°CMaximum working pressure 50 MpaElectrical ratingsModel Without arrester:Ui 45 Vdc, 4-20 mAModel With arrester:Ui 32 Vdc, 4-20 mANote: "Seal not required"Ex d IIC T6 (-40°C Ta +65 °C)Ex d IIC T5 (-40°C Ta +85 °C)DIP A21 IP66/67 T 85°CDIP A21 IP66/67 T 100°CElectrical ratingsModel Without arrester:Ui 45 Vdc, 4-20 mA loop powered, Pi 1.0125 WModel With arrester:Ui 32 Vdc, 4-20 mA loop powered, Pi 1.0125 W2