12.07.2015 Views

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens AG <strong>2012</strong>For Use in the Control CabinetET 200S Motor Starters and Safety Motor StartersHigh-Feature motor starters■ OverviewFunctionality of the High-Feature motor starters• Basic functionality see "General Data" ➞ "Overview"on page 8/84.• Direct-on-line, reversing or soft starter up to 7.5 kW• With wide range in 3 setting ranges, with 0.3 to 3 A,2.4 up to 8 A, 2.4 to 16 A available• With combination of starter circuit breaker, electronic overloadprotection (parameterizable), and contactor or soft starter• Power bus up to 50 A• Upper and lower current limits for plant and process monitoring• Motor stall protection, zero current detection and asymmetrydetection integrated• The actual motor current is measured and transmitted fordiagnostics in the cyclic process image• Control of the motor starter from the control system and extensivediagnostics status via the cyclic process image• Optional digital inputs available in the cyclic process imageand flexibly assignable with functions for adaptation to allapplications• Detection of the switching state of the starter circuit breaker viaaux. switches and of the contactor via current evaluation• Integrated isolating function using starter circuit breakers• Local safety engineering possible (without failsafe kit in thecase of the HF starter, because the function of the failsafe kit isalready integrated)• Front-mounting 2DI LC COM control module for 2 moreparameterizable digital inputs• Optional "Motor Starter ES" software for easy commissioningand diagnostics - from 11/2011 also for the new .-.AB4 -Starteravailable (see Chapter 14 "Parametrization, Configuration andVisualization with SIRIUS")• PROFIenergy capable (only with the new .-.AB4 -starters)• Supplying the motor current in PROFIenergy format- Switching off during dead times• All acyclic services DPV1 supported by PROFIBUS andPROFINET (only with the new .-.AB4 -starters)- Changing of parameters during operation, e.g. the ratedoperational current- Reading and writing acyclic data for exact diagnostics of theunit or process and for analysis of the plant statusSelective protection concept forET 200S High-Feature motor startersAs a result of the selective protection concept (separate trippingof short circuit and overload) with solid-state overload evaluation,additional advantages are realized on the High-Feature motorstarters – advantages which soon make themselves positivelyfelt particularly in manufacturing processes with high plantstoppage costs:• Only two versions up to 7.5 kW – hence little order variance andstock keeping• All settings can be parameterized by bus – hence fullTIA capability• Separate signaling of overload and short circuit – enablesselective diagnostics• Overload can be acknowledged by remote reset – ideal forhighly automated plants• Current asymmetry monitoring – complete monitoring of themotor• Stall protection – complete monitoring of the motor• Emergency start function in case of overload – operation is possiblein an emergency• Current value transmission via bus – monitoring of the application• Current limit monitoring• Trip class can be parameterized – overload trip can be adaptedto the application• Type of coordination "2" – still functional after short circuit withmagnitude of 50 kA• Very high contact enduranceET 200S High-Feature motor starter: DS1e-x direct-on-line starter(innovated .-.AB4 starters)ET 200S High-Feature motor starter: DS1e-x direct-on-line soft starter(innovated .-.AB4 starter)ET 200S High-Feature motor starter: Reversing starter (reversing starter)RS1e-x (innovated .-.AB4 -Starter)8Siemens <strong>IC</strong> <strong>10</strong> · <strong>2012</strong>8/93

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!