12.07.2015 Views

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens AG <strong>2012</strong>For Use in the Control CabinetET 200S Motor Starters and Safety Motor Starters8High-Feature motor startersPROFIenergy for ET 200S High-Feature motor starters 1)Increasing energy prices, far-reaching ecological problemsworldwide and the threat of climate change make it necessaryfor you to be more conscious about your use of energy.Active and effective energy management is possible withPROFIenergy.PROFIenergy is a manufacturer-independent profile onPROFINET, which can be used by all manufacturers, has beenstandardized by PNO 1) and supports the shut-down of electricaldevices during dead times and the read-out of measured values.The ET 200S HF motor starter supplies the motor current inPROFIenergy format and switches off during dead times.All acyclic services DPV1 supported by PROFIBUS andPROFINET (only with the new .-.AB4 -starters)Thanks to the acyclic services, the ET 200S HF motor startersnow offer plenty of diagnostics data via data records. There areextensive new options for reading out data from the motor starterfor device, system or process monitoring. The motor starter isequipped internally with three logbooks for device faults, motorstarter trips and events, which are issued with a time stamp.These logbooks can be read out of the motor starter on demandat any time and provide the plant operator with plenty of informationabout the state of his plant and process which he can use tocarry out improvements.With the slave pointer and statistical data functions it is possibleto read out, for example, the maximum internal current values orthe number of motor starter connection operations. This enablesprocess deviations to be monitored or commissioning to be optimized.Statistical data or measured values make plant monitoring easyfor the user.The device diagnostics data record contains details of all thestates of the motor starter, the device configuration and the communicationas a basis for central device and plant monitoring.■ Technical specificationsSee page 8/89.The Installation and Maintenance Functions (I&M) store, firstly,information (I&M) about the modules used in the motor starterand, secondly, data (I&M) that can be defined during configuration,e.g. location designations. I&M functions are used for fortroubleshooting faults and localizing changes in hardware at aplant or checking the system configuration.Supported data records:• DS 0 S7-V1 system diagnostics (S7 diagnostics alarm)• DS 72, 73, 75 logbooks, device faults, trips, events• DS 92 device diagnostics• DS 93 command• DS 94 measured values• DS 95 statistics• DS 96 slave pointer• DS <strong>10</strong>0 device identification• DS 131 device parameters• DS 134 maintenance• DS 165 comment• DS 226 PROFIenergy technology function• DS 231 I&M 0 (= device identification)• DS 232 I&M 1 (= equipment identifier)• DS 233 I&M 2 (= installation)• DS 234 I&M 3 (= description)Device functions (firmware features)See page 8/86 and 8/87.1) In the PNO (PROFIBUS Nutzerorganisation e. V. - PROFIBUS User Organization),manufacturers and users have come together to agree on the standardizedcommunication technologies PROFIBUS and PROFINET.8/94 Siemens <strong>IC</strong> <strong>10</strong> · <strong>2012</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!