12.07.2015 Views

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

Catalog IC 10 · 2012 - Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For Use in the Control CabinetET 200S Motor Starters and Safety Motor StartersGeneral data© Siemens AG <strong>2012</strong>8SIMAT<strong>IC</strong> ET 200SSIMAT<strong>IC</strong> ET 200SStandard motor starters High-Feature motor starters 1)Device functions (firmware features)Slave on the busFieldbus ✓ Dependent on the interface moduleParameterizationPROFIBUS / PROFINET data records -- ✓Parameterization using data record start -- ✓DiagnosticsAcyclic through data records -- ✓Support of diagnostics alarm✓Diagnostics using PROFIBUS/PROFINET -- ✓ See manualProcess imageProcess image ✓ 3I/3O ✓ 16I/7OAddress area required per module ✓ 4 bits ✓ 2 byteData channelsOperator terminal interface -- ✓ Through moduleMotor Starter ES through local interface -- ✓ Starting end of 2011Motor Starter ES through bus -- ✓ Starting end of 2011Data records (acyclic)Parameterization -- ✓Support for PROFIenergy profile -- ✓ Measuring the motor current and disconnectionin dead timesDiagnostics -- ✓Measured values -- ✓Statistics -- ✓Commands -- ✓Slave pointer -- ✓Logbook -- ✓Device identification -- ✓I&M data -- ✓InputsNumber ✓ Maximum 2, via xB3, xB4, xB6 ✓ Maximum 4, 2 via xB3, xB4, xB6 and2 via module 2DI 24 V DC COM• Of these in the process image -- ✓ 4Input action ✓ End position on left, right ✓ Parameterizable: FlexibleQuick-Stop -- ✓ ParameterizableOutputsNumber ✓ Internal, for controlling the brake moduleOutput action ✓ BrakeBrake output with additional moduleMotor brake voltage: brake module ✓ 24 V DC: xB1/xB3, 500 V DC: xB2/xB4, 400 V AC: xB5/xB6Motor protectionOverload protection ✓ Thermal, range 1:1.3 ✓ Electronic, wide range 1:<strong>10</strong>Overload warning -- Only tripping ✓Short-circuit protection ✓ Circuit breaker ✓Full motor protection --Motor protection response in case of overloadThermal motor model reaction✓ Function is available-- Function not available-- ✓ Parameterizable: disconnection without restart,disconnection with restart, warningAuto reset --Temperature sensor --Emergency start function -- (✓ with 3RK1 903-0CG00 control unit) ✓1) The device functions mentioned apply in full only to the new.-.AB4 starters.8/86 Siemens <strong>IC</strong> <strong>10</strong> · <strong>2012</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!