© Siemens AG <strong>2012</strong>For Use in the Control CabinetET 200S Motor Starters and Safety Motor StartersSafety modules local and PROFIsafeComponents for ET 200S Safety Motor Starter Solution localThe ET 200S Safety Motor Starter Solutions local comprise:Version 1 (see example 1 on page 8/<strong>10</strong>5):• Safety modules PMD F1 ... 5• PM-X module• Standard motor starter or High-Feature motor starterVersion 2 (see example 2 on page 8/<strong>10</strong>5):• PM-D FX1 safety module• Failsafe motor startersFunctionality of the ET 200S Safety Motor Starter Solutions local• For use of Standard, High-Feature or Failsafe motor starters insystems with safety categories 2 to 4(according to ISO 13849-1)• Can also be used in combination with external safety relays• Can also be used to activate external safety systems• No complex wiring for conventional safety technology• Safety module available for function-monitored and automaticstarting• Safety module available for Stop category 0 and 1• Safety module for monitoring the auxiliary voltages for motorstarters• Safety modules can be plugged into the TM-PF30 terminalmodulesWith Safety motor starters Solutions local the highest safety categorycan be reached according to ISO 13849-1 and IEC 62061.They can thus be used for evaluation of EMERGENCY-STOP circuitsor for monitoring protective doors and also for time-delayeddisconnections. With the contact multiplier the safety-relevantsignals can also be made available to external systems.All standard safety applications can be covered through combinationof different TM-PF30 terminal modules. Needless to say,ET 200S motor starters can also be used in conjunction withexternal safety relays or with ASIsafe.Safety motor starter Solutions local reduce wiring by up to 80 %compared to conventional safety systems with local safety applications.With the Safety motor starters Solutions local it is easy to installseveral safety circuits. The safety sensors are connected directlyand locally to the safety modules. These safety modules performthe work of the otherwise obligatory safety relays and safely shutdown the downstream motor starters in accordance with thefunction selected. The crosslinks required for this are already integratedin the system and need no additional wiring. All signalsfrom the safety modules are automatically relayed as diagnosticsignals, e.g. in the event of crossover in the EMERGENCY-STOPcircuit.The safety module evaluates the signal state of the connectedsafety sensors and, using the integrated safety relays, shutsdown the group(s) of downstream motor starters. The shutdownfunction is monitored by the module, and the auxiliary voltageslikewise.Safety-relevant system signals, e.g. caused by an actuatedEMERGENCY-STOP switch or a missing auxiliary voltage, areautomatically generated and notified to the interface module.The latter assigns an unambiguous ID to the fault. Using thePROFIBUS DP diagnostics block, faults of this type can be identifiedand localized without a great deal of programming work.PM-D F1/F2/F3/F4/F5 safety modules• PM-D F1/F2/F3/F4 safety modules monitor auxiliary voltagesand contain the complete functionality of a safety relay:- PM-D F1: For evaluation of EMERGENCY-STOP circuits withthe function "Monitored start"- PM-D F2 For monitoring of protective doors with the function"automatic start".- PM-D F3: Expansion to PM-D F1/F2 for time-delayed disconnection.- PM-D F4: For expanding safety circuits with other ET 200Smotor starters, e. g. in a different tier- PM-D F5: Transmits the status from PM-D F1 ... 4 via fourfloating enabling circuits to external safety devices (contactmultipliers)• The PM-D F1 and PM-D F2 modules can be combined withthe PM-D F3 or PM-D F4 modules.• A PM-D F5 can be positioned at any point between aPM-D F1 ... 4 and a PM-X 1) .• Safety modules monitor the U1 and U2 auxiliary voltages.A voltage failure is relayed as a diagnostic signal over the bus.- No additional PM-D safety module is required when thesafety modules are used.- Each safety circuit, beginning with a PM-D F1 ... 4, must beterminated with one PM-X each 1) .1) See "Accessories for Safety modules Local" on page 8/116.PM-D F1 safety modulePM-D FX1 safety moduleThe PM-D FX1 safety module is used for feeding in 1 to 6 switchoffgroups. The infeed voltage can be switched using 1 to 6 externalsafety shutdown devices (either ASIsafe monitors or3TK28 safety relays). This safety module is used in applicationswith external safety shutdown devices where there is a need forthe fully selective safety shutdown of failsafe motor starters/frequencyconverters (example 2 on page 8/<strong>10</strong>5).Terminal modules for (TM-PF30) safety moduleFor feeding load and sensor voltage to the potential bars of themotor starters, and for the connection of the 2-channel sensorcircuit (e.g. EMERGENCY-STOP pushbutton) and a RESET button.Different terminal modules are available for the configuringof separate safety circuits or for the cascading of safety circuits,and for applications with time-delayed disconnection (seepage 8/111).8Siemens <strong>IC</strong> <strong>10</strong> · <strong>2012</strong>8/<strong>10</strong>3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!