F. Each channel shall have an inner and outer filtration element and filter element support made <strong>of</strong> 304 stainlesssteel. <strong>The</strong> filter element supports shall be mounted and attached to the common drive shaft that is directly attachedto the gear reduction drive <strong>of</strong> the Rotary Fan Press. Under maximum loading conditions, the elementsupports shall not have a deflection greater than 0.005” over the entire surface area or require internal bearingsfor support <strong>of</strong> the element support wheels.G. <strong>The</strong> dewatering channel filtration elements shall be constructed <strong>of</strong> two (2) slotted non-clogging filter screenswith supports constructed <strong>of</strong> 304 stainless steel, separated and sealed by a poly-glass filled channel center seal.H. Each <strong>of</strong> the Rotary Fan Press dewatering channels shall have both internal and external filter wash options. <strong>The</strong>wash water time intervals shall be operator directed through the main operator panel. Washing <strong>of</strong> the filter elementsshall be capable <strong>of</strong> being done without interrupting the dewatering process at any time. <strong>The</strong> Rotary FanPress internal filter screen wash requires sixteen (16) gpm at a minimum <strong>of</strong> forty-five (45) psi per channel andthe external filter screen wash requires sixteen (16) gpm at a minimum <strong>of</strong> forty-five (45) psi per channel. <strong>The</strong>incoming water connection shall be 1-1/2” FNPT to the distribution manifold which contain the 110V solenoidoperated valves for controlling the water flow.I. Each dewatering channel shall have a tapered pneumatic adjustable self-compensating glass filled poly sludgecake restrictor gate. With the restrictor gate in its fully open position it shall not restrict the sludge cake openingin any way.J. Individual 304 stainless steel cake discharge chutes shall be provided for each dewatering channel. Each cakedischarge chute shall have an easy to remove inspection cover to gain access to the cake discharge area <strong>of</strong> theRotary Fan Press.2.04 – Sludge Feed PumpA. A positive displacement <strong>rotary</strong> lobe sludge feed pump shall be used to provide adjustable and even feeding <strong>of</strong>the sludge stream to the <strong>press</strong>. <strong>The</strong> sludge feed pump shall be capable <strong>of</strong> supplying 125% <strong>of</strong> the specifiedmaximum speed, not to exceed four hundred-fifty (450) rpm. This combination shall be direct coupled andmounted on one (1) common base and securely fastened to the <strong>trailer</strong> floor. Progressive cavity pumps are notacceptable for this <strong>specification</strong>.1. Rotary Lobe Pump Will Be “Böerger” or Equal.15-120 gpm Under 450 rpm.Suction 3”, Discharge 3”, 150# ANSI Flanged Stainless Steel.Epoxy Coated per Section 2.13.2. Pump Drive Will Be “Nord” or Equal.5 hp with A Min 1.15 sf.Ratio: 4:1Epoxy Coated per Section 2.13.2.05 – Electrical Control Panel (General)A. An electrical control panel shall be furnished with the Rotary Fan Press Trailer System to control the Rotary FanPress functions and those <strong>of</strong> related ancillary equipment specified herein. <strong>The</strong> panel shall be pre-assembled,pre-wired and shall include all controls necessary for semi-automatic and manual <strong>system</strong> operations. <strong>The</strong> panelshall be suitably wired for connection to a 480 Volt, 3 Phase, 60 Hertz power source. A step down transformerprovides 120V AC control power and the DC voltage shall be 24V.B. Wiring shall be accomplished in a neat and organized manner through PVC wire duct, where practical, and tiedsecurely in position with nylon cable ties when not. All <strong>trailer</strong> mounted conduit shall be Schedule 40 PVCand/or non-metallic liquid tight conduit.Rotary Press Trailer System Specification Page 9 <strong>of</strong> 16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!