12.07.2015 Views

CBX 24 & 32 SBX 30 - Trademate Home Page

CBX 24 & 32 SBX 30 - Trademate Home Page

CBX 24 & 32 SBX 30 - Trademate Home Page

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For installation details refer to the instructions provided with theopened flued kit.Maximum flue resistance permitted for an openedflued system = 100 Pa.Minimum flue resistance permitted for an openedflued system = 38 Pa.Flue ComponentFlue Resistance Part Number(Pa)Air inlet Assembly (required) 9 -60/80 Adaptor (required) 12 -Terminal (required) 9 -91.5° Elbow (80) (required) 8 -80 diameter Corrugated (required) 2/metre -80 mm diameter straight duct 2/metre -Horizontal Flue Adaptor 15 956086Vertical Flue Adaptor 0 95608793° Elbow (60/100) 15 95609145° Elbow (60/100) 7 9560903fChimney flue liner kit - Part no. 956082Chimney terminal2.7 KIT F: SPLIT PIPE VERTICAL FLUEOUTLET (C53) - PART NO. 956080This flue system kit is designed for installations where the air intake position isdifferent from the flue duct exit point. The kit comprises a twin adaptor fromthe which the air intake is taken from the adjacent outside wall (see exampleFigure 3g) and the flue duct is routed vertically through the roof.It has to be noted that the flue duct is under pressure when the appliance isin operation and the duct can leak poisonous carbon monoxide if the ductcomponents are not correctly assembled. It is not recommended to route theflue duct through living space areas, i.e. bed rooms, living rooms etc.For C5 flue systems the terminals for the supply of combustion air and for theevacuation of combustion products shall not be installed on opposite walls ofthe building.For installation details refer to the instructions provided with the twin flued kit.Maximum flue resistance permitted for a twin fluedsystem = 120 PaMinimum flue resistance permitted for a twin fluedsystem = 66 PaFlue Component Flue Resistance (Pa) Part NumberTwin Flue Adaptor (required) <strong>30</strong> -Air Inlet Terminal (required) 9 -Flue Outlet Terminal (required) 27 -80 mm diameter straight duct 2/metre 95610290° Elbow (80/80) 8 95610045° Elbow (80/80) 4 956099!In replacement installations,the chimney has to becleared of debris andall flue parts.Centralising brackets93 flanged elbow (concentric)with sampling pointFlexible corrugated plastic flue linerØ80mm according to EN 14471Max. length <strong>30</strong>m.Min. length 5m.3gSplit pipe verticalflue outlet kit -Part no. 956080The flue resistance for thefollowing accessories hasto be considered.Ø80mm flue extension90 elbow45 elbowMax. flue length <strong>30</strong>m.If the flue pipe passesthrough habitable roomswithin the same dwelling,the flue pipe must berouted through ventedair ducts.! !Roof terminal with pitchedroof flashing kit.If the flue pipe passesthrough compartmentfrom wall/floors, therequirements set outin Building RegulationsPart B must be followed.ChimneyplateØ60/100mm concentricchimney adaptor pipe.Ø80mm twin adaptorwith sampling point.Ø80mm air intakeKIT EA flue system can be built up from the componentsdetailed in the table, but the total flue resistance mustnot exceed the maximum stated.Split flue systemKit FA flue system can be built up from the componentsdetailed in the table, but the total flue resistance mustnot exceed the maximum stated.7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!