12.07.2015 Views

Sauer-Danfoss series OTP steering columns

Sauer-Danfoss series OTP steering columns

Sauer-Danfoss series OTP steering columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>OTP</strong> Steering Columns / OVPL, OVR Valve BlocksTechnical InformationFixed Steering Columns, <strong>OTP</strong>InstallationInstallation of <strong>steering</strong> column with A-flange<strong>Sauer</strong>-<strong>Danfoss</strong> <strong>steering</strong> column with A-flange can be mounted on the cabin floor, andthe <strong>Sauer</strong>-<strong>Danfoss</strong> <strong>steering</strong> unit can be mounted under the cabin floor. The S-dimensionhas to be equal to the thickness of the cabin floor + 6.5 mm [0.26 in]. Example: If thecabin floor is 4 mm [0.16in], then S = 4 + 6.5 = 10.5 mm [0.16 + 0.26 = .0.41 in] CautionThe <strong>steering</strong> column must be coaxial with the splined connection of the <strong>steering</strong> unit:It must be guaranteed that the shaft of the <strong>steering</strong> column generates no radial and/oraxial forces in the splined connection of the <strong>steering</strong> unit.Max tightening torque for fixing screws is 30 N•m [265.5 lbf•in]. Recommendedtightening torque for the <strong>steering</strong> wheel connection is 40 ±5 N•m [354 ±44 lbf•in].26 11015554 • Rev AB • May 2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!