12.07.2015 Views

Glenair Mighty Mouse Connectors Catalog - Interstate Connecting ...

Glenair Mighty Mouse Connectors Catalog - Interstate Connecting ...

Glenair Mighty Mouse Connectors Catalog - Interstate Connecting ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ReferenceSeries 80 <strong>Mighty</strong> <strong>Mouse</strong> Technical ReferenceComplete Product SpecificationADESCRIPTION REQUIREMENT PROCEDUREBCD21 day humidity (dampheat, long term)Thermal shockNo deterioration which will adversely affectthe connector. Following the drying period,connectors shall meet 100 megohmsminimum, contact resistance, shell-to-shellresistance, DWV, mating and unmatingrequirements.No mechanical damage or loosening ofparts. Following thermal shock, connectorshall meet contact resistance, DWV,insulation resistance and shell-to-shellresistance requirements.EIA-364-31 Condition C Method IIIEC-60512-11-3 Severity C90-95% RH40° CApply 100 volts DC during test. 4 hoursdrying time at ambient temperatureprior to final measurements.EIA-364-32 Test Condition IVIEC-60512-11-45 cycles consisting of -65° C 30minutes, +25° C 5 minutes max., +150°C 30 minutes, +25° C 5 minutes max.EFGCorrosion (salt mist)No exposure of base metal. <strong>Connectors</strong>shall meet DWV and contact resistancerequirements following the test.EIA-364-26IEC 60512-11-65% salt solution35° CUnmated connectorsCode C: 48 hoursCode M: 48hoursCode MT: 500 hoursCode NF: 500 hoursCode ZN: 500 hoursCode ZNU: 500 hoursCode UCR: 500 hoursHSand and dustMated connectors shall withstand the effectsof blowing sand and dustMIL-STD-810F, Method 510.4Fungus Connector materials shall be fungus inert. MIL-STD-810F, Method 508.5JFluid immersionNo visible damage from immersion invarious fuels and oils. Connector shall meetcoupling torque and dielectric withstandingvoltage requirements.EIA-364-10Unmated connectorsKLAltitude immersionNo evidence of moisture on connectorinterface or contacts. Connector shall meetdielectric withstanding voltage.EIA-364-03Wired crimp connectors withsupplemental potting. Printed circuitboard and solder cup connectors withstandard factory-installed potting.OutgassingThe entire connector assembly shall be capableof meeting a maximum Total Mass Loss (TML) of1% and a Total Collected Volatile Material Loss(TCVML) of 0.1% following additional processingfor outgassing control.ASTM-E595Dimensions in inches (millimeters) and are subject to change without notice.© 2010 <strong>Glenair</strong>, Inc. CAGE Code 06324 Printed in U.S.A.GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912www.glenair.com B-28 E-Mail: sales@glenair.com01-JANUARY-2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!