12.07.2015 Views

Analytical Chem istry - DePauw University

Analytical Chem istry - DePauw University

Analytical Chem istry - DePauw University

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

198 <strong>Analytical</strong> <strong>Chem</strong><strong>istry</strong> 2.05IProblemsAnswers, but not worked solutions, tomost end-of-chapter problems are availablehere.1. Describe how you would use a serial dilution to prepare 100 mL eachof a series of standards with concentrations of 1.00×10 –5 , 1.00×10 –4 ,1.00×10 –3 , and 1.00×10 –2 M from a 0.100 M stock solution. Calculatethe uncertainty for each solution using a propagation of uncertainty,and compare to the uncertainty if you were to prepare each solution bya single dilution of the stock solution. You will find tolerances for differenttypes of volumetric glassware and digital pipets in Table 4.2 andTable 4.3. Assume that the uncertainty in the stock solution’s molarityis ±0.002.2. Three replicate determinations of S total for a standard solution that is10.0 ppm in analyte give values of 0.163, 0.157, and 0.161 (arbitraryunits). The signal for the reagent blank is 0.002. Calculate the concentrationof analyte in a sample with a signal of 0.118.3. A 10.00-g sample containing an analyte is transferred to a 250-mLvolumetric flask and diluted to volume. When a 10.00 mL aliquot ofthe resulting solution is diluted to 25.00 mL it gives signal of 0.235(arbitrary units). A second 10.00-mL portion of the solution is spikedwith 10.00 mL of a 1.00-ppm standard solution of the analyte and dilutedto 25.00 mL. The signal for the spiked sample is 0.502. Calculatethe weight percent of analyte in the original sample.4. A 50.00 mL sample containing an analyte gives a signal of 11.5 (arbitraryunits). A second 50 mL aliquot of the sample, which is spiked with1.00 mL of a 10.0-ppm standard solution of the analyte, gives a signalof 23.1. What is the analyte’s concentration in the original sample?5. An appropriate standard additions calibration curve based on equation5.10 places S spike ×(V o + V std ) on the y-axis and C std ×V std on the x-axis.Clearly explain why you can not plot S spike on the y-axis and C std ×[V std /(V o + V std )] on the x-axis. In addition, derive equations for the slopeand y-intercept, and explain how you can determine the amount ofanalyte in a sample from the calibration curve.6. A standard sample contains 10.0 mg/L of analyte and 15.0 mg/L ofinternal standard. Analysis of the sample gives signals for the analyteand internal standard of 0.155 and 0.233 (arbitrary units), respectively.Sufficient internal standard is added to a sample to make its concentration15.0 mg/L Analysis of the sample yields signals for the analyte andinternal standard of 0.274 and 0.198, respectively. Report the analyte’sconcentration in the sample.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!