12.07.2015 Views

Model YCUL Air-Cooled Scroll Compressor ... - Usair-eng.com

Model YCUL Air-Cooled Scroll Compressor ... - Usair-eng.com

Model YCUL Air-Cooled Scroll Compressor ... - Usair-eng.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SpecificationGENERALThe 40 - 80 Ton (140 - 281 kW) <strong>YCUL</strong> models are shipped<strong>com</strong>plete from the factory ready for installation and use.The unit is pressure-tested, evacuated and given a nitrogenholding charge and includes an initial oil charge(R-410A refrigerant supplied by others). After assembly, aoperational test is performed to assure that each controldevice operates correctly.The unit structure is heavy-gauge, galvanized steel.This galvanized steel is coated with baked-on powderpaint, which, when subjected to ASTM B117 1000 hour,salt spray testing, yields a minimum ASTM 1654 ratingof “6”. Units are designed in accordance with NFPA 70(National Electric Code), ASHRAE/ANSI 15 Safety codefor mechanical refrigeration, and are cETL listed. All unitsare produced at an ISO 9000-registered facility.COMPRESSORSThe chiller has suction-gas cooled, hermetic, scroll <strong>com</strong>pressors.The <strong>YCUL</strong> <strong>com</strong>pressors incorporate a scroll designthat is <strong>com</strong>pliant in both the axial and radial direction.All rotating parts are statically and dynamically balanced.A large internal volume and oil reservoir provides greaterliquid tolerance. <strong>Compressor</strong> crankcase heaters are alsoincluded for extra protection against liquid migration.CONDENSERCoils – Fin and tube condenser coils of seamless, internally-enhanced,high-condensing-coefficient, corrosionresistant copper tubes are arranged in staggered rows,mechanically expanded into aluminum fins. Integralsubcooling is included. The design working pressure ofthe coil is 650 PSIG (45 barg).Low Sound Fans – The condenser fans are <strong>com</strong>posed ofcorrosion resistant aluminum hub and <strong>com</strong>posite bladesmolded into a low noise airfoil section. They are designedfor maximum efficiency and are statically and dynamicallybalanced for vibration-free operation. They are directlydriven, and positioned for vertical air discharge. The fanguards are constructed of heavy-gauge, rust-resistant,PVC (polyvinyl chloride)-coated steel wire.Motors – The fan motors are Totally Enclosed <strong>Air</strong>-Over,squirrel-cage type, current protected. They feature ballbearings that are double-sealed and permanently lubricated.JOHNSON CONTROLS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!