FORM 150.68-EG1 (1109)1. Coils: Internally enhanced, seamless coppertubes, mechanically expanded into aluminumalloy fins with full height collars. Subcooling coilan integral part of condenser. Design workingpressure shall be 650 psig (45 barg).2. Fans: Shall be dynamically and statically balanced,direct drive, corrosion resistant glass fiberreinforced <strong>com</strong>posite blades molded into lownoise, full airfoil cross section, providing verticalair discharge from extended orifices for efficiencyand low sound. Each fan in its own <strong>com</strong>partmentto prevent cross flow during fan cycling. Guardsof heavy gauge PVC (polyvinyl chloride) coatedsteel.3. Fan Motors: High efficiency, direct drive, 6 pole,3 phase, insulation class “F”, current-protected,Totally Enclosed <strong>Air</strong>-Over (TEAO), rigid mounted,with double sealed, permanently lubricated, ballbearings.2.05 CONTROLSA. General: Automatic start, stop, operating, and protectionsequences across the range of scheduledconditions and transients.B. Microprocessor Enclosure: Rain and dust tight NEMA3R/12 (IP55) powder painted steel cabinet withhinged, latched, and gasket sealed door.C. Microprocessor Control Center:1. Condensing Unit control is set for Discharge <strong>Air</strong>Temperature Control2. Automatic control of <strong>com</strong>pressor start/stop, anticoincidenceand anti-recycle timers, automaticpump-down shut-down, condenser fans, unitalarm contacts, and condensing unit operationfrom 0°F to 125°F (-18°C to 52°C) ambient. Automaticreset to normal chiller operation after powerfailure.3. Software stored in non-volatile memory, withprogrammed set-points retained in lithium battery-backedreal time clock (RTC) memory forminimum 5 years.4. Forty character liquid crystal display, descriptionsin English (or Spanish, French, Italian, orGerman), numeric data in English (or Metric)units. Sealed keypad with sections for Setpoints,Display/Print, Entry, Unit Options & clock, andOn/Off Switch.5. Programmable Set-points (within Manufacturerlimits): display language; suction pressure settingand control range, remote reset temperaturerange, set daily schedule/holiday for start/stop,manual override for servicing, low and highambient cutouts, number of <strong>com</strong>pressors, lowsuction pressure cutout, high discharge pressurecutout, anti-recycle timer (<strong>com</strong>pressor start cycletime), and anticoincident timer (delay <strong>com</strong>pressorstarts).6. Display Data: Suction temperatures (optional),low ambient temperature cutout setting, outdoorair temperature, English or metric data, suctionpressure cutout setting, each system suction pressure,discharge pressure (optional), discharge airreset via Building Automation System (by others)via a 4-20milliamp or 0-10 VDC input with optionalBAS interface, anti-recycle timer status for eachsystem, anti-coincident system start timer condition,<strong>com</strong>pressor run status, no cooling loadcondition, day, date and time, daily start/stoptimes, holiday status, automatic or manual systemlead/lag control (when controlling based onDischarge <strong>Air</strong> Temperature only), automatic lead/lag of <strong>com</strong>pressors within a system, <strong>com</strong>pressorstarts/operating hours (each), status of hot gasvalves, and fan operation, run permissive status,number of <strong>com</strong>pressors running, liquid solenoidvalve status, load & unload timer status.7. System Safeties: Shall cause individual <strong>com</strong>pressorsystems to perform auto shut down; manualreset required after the third trip in 90 minutes.Includes: high discharge pressure, low suctionpressure, high pressure switch, and motor protector.<strong>Compressor</strong> motor protector shall protectagainst damage due to high input current orthermal overload of windings.8. Unit Safeties: Shall be automatic reset and cause<strong>com</strong>pressors to shut down if low ambient, or undervoltage.9. Alarm Contacts: Low ambient, low voltage, lowbattery, and (per <strong>com</strong>pressor circuit): high dischargepressure, and low suction pressure.10. High Ambient Control: Permits unit operationabove 115°F (46°C) ambient.D. Manufacturer shall provide any controls not listedabove, necessary for automatic condensing unitoperation. Mechanical Contractor shall provide fieldcontrol wiring necessary to interface sensors to thecondensing unit control system.2.06 POWER CONNECTION AND DISTRIBUTIONA. Power Panels:1. NEMA 3R/12 (IP55) rain/dust tight, powderpainted steel cabinets with hinged, latched, andJOHNSON CONTROLS 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!