12.07.2015 Views

LT-2002 MR-2100_2200 Operator's Manual Rev.0 - Secutron

LT-2002 MR-2100_2200 Operator's Manual Rev.0 - Secutron

LT-2002 MR-2100_2200 Operator's Manual Rev.0 - Secutron

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MR</strong>-<strong>2100</strong>/<strong>2200</strong> Operator’s <strong>Manual</strong>2.2 Miscellaneous TroublesThis is a list of all possible messages that can be displayed by Miscellaneous Trouble on the LCD.Only those conditions that are in trouble will be shown. Some of the messages are alwaysdisplayed if the panel is in Test Mode.MessagePROGRAM checksumEEPROM checksumDATABASE checksumEEPROM failurenot enough EEPROM tosave addressablesettingsprogram mismatchhardware mismatchno database loadedwrong databaseversion or databasemismatchno database for thispanellow batteryDescriptionThe memory chip containing the operating program has an error in it.Reloading the operating program will correct this problem. If this errorkeeps reoccurring, the unit will need replacement.The memory chip containing the configuration information has an errorin it. Changing a value of an item set through the LCD menu will causethe panel to create a new checksum. If this error keeps reoccurring, theunit will need replacement.The memory chip containing the downloaded database has an error init. Reloading the database will correct this problem. If this error keepsoccurring, the unit will need replacement.The memory chip containing the configuration information is not workingcorrectly. It will need to be erased. This requires a Level 9 passcode.Erasing the EEPROM will lose ALL information in the EEPROM. Thisincludes the configuration information, the panel serial number and thearchive. Be sure to record this information before you erase theEEPROM. Contact a service representative for help and a Level 9passcode.The panel has a 64k EEPROM. The addressable device bypasses andthe manual operation of control modules requires a 256k EEPROM forthe settings to be retained when the panel is rebooted. Note: This willnot cause a common trouble on the panel.The version number stored in the EEPROM is different from the versionnumber in the program. Either reload the old program or erase theEEPROM. Erasing the EEPROM requires Privilege Level 9. Erasing theEEPROM will lose ALL information in the EEPROM. This includes theconfiguration information, the panel serial number and the archive. Besure to record this information before you erase the EEPROM. Contacta service representative for help and a Level 9 passcode.The hardware listed in the database does not match the hardware listedin the panel. Correct the database and reload.The panel does not have a database in memory. Load a database intothe panel.The database is the incorrect version for the operating program running.Download a database with the same version number as the operatingprogram.The panel contains a valid database, but the database does not containthe information for this panel. Either change the panel ID to the correctvalue, or load a database that includes the panel's ID.The battery needs recharging or replacement.11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!