<strong>Cluster</strong> Storage Devices<br />

6.2 Naming <strong>OpenVMS</strong> <strong>Cluster</strong> Storage Devices<br />

6.2.2.3 Assigning Node Allocation Class Values on HSJ Subsystems<br />

To assign a node allocation class value for disks for an HSJ subsystem, enter a<br />

SET CONTROLLER MSCP_ALLOCATION_CLASS command in the following<br />

format:<br />

SET CONTROLLER MSCP_ALLOCATION_CLASS = allocation-class-value<br />

To assign a node allocation class value for tapes, enter a SET CONTROLLER<br />

TMSCP_ALLOCATION_CLASS ALLOCATE TAPE command in the following<br />

format:<br />

SET CONTROLLER TMSCP_ALLOCATION_CLASS = allocation-class-value<br />

For example, to assign or change the node allocation class value for disks to 254<br />

on an HSJ subsystem, use the following command at the HSJ console prompt<br />

(PTMAN>):<br />

PTMAN> SET CONTROLLER MSCP_ALLOCATION_CLASS = 254<br />

6.2.2.4 Assigning Node Allocation Class Values on HSD Subsystems<br />

To assign or change allocation class values on any HSD subsystem, use the<br />

following commands:<br />

$ MC SYSMAN IO CONNECT FYA0:/NOADAP/DRIVER=SYS$FYDRIVER<br />

$ SET HOST/DUP/SERVER=MSCP$DUP/TASK=DIRECT node-name<br />

$ SET HOST/DUP/SERVER=MSCP$DUP/TASK=PARAMS node-name<br />

PARAMS> SET FORCEUNI 0<br />

PARAMS> SET ALLCLASS 143<br />

PARAMS> SET UNITNUM 900<br />

PARAMS> WRITE<br />

Changes require controller initialization, ok? [Y/(N)] Y<br />

PARAMS> EXIT<br />

$<br />

6.2.2.5 Assigning Node Allocation Class Values on DSSI ISEs<br />

To assign or change node allocation class values on any DSSI ISE, the command<br />

you use differs depending on the operating system.<br />

For example, to change the allocation class value to 1 for a DSSI ISE TRACER,<br />

follow the steps in Table 6–2.<br />

6–10 <strong>Cluster</strong> Storage Devices<br />

Table 6–2 Changing a DSSI Allocation Class Value<br />

Step Task<br />

1 Log into the SYSTEM account on the computer connected to the hardware device TRACER<br />

and load its driver as follows:<br />

• If the computer is an Alpha system, then enter the following command at the DCL<br />

prompt:<br />

$ MC SYSMAN IO CONN FYA0:/NOADAP/DRIVER=SYS$FYDRIVER<br />

• If the computer is a VAX system, then enter the following command at the DCL<br />

prompt:<br />

$ MCR SYSGEN CONN FYA0:/NOADAP/DRIVER=FYDRIVER<br />

(continued on next page)