<strong>Cluster</strong> Troubleshooting<br />

C.10 Diagnosing Port Failures<br />

2. The configuration poller makes entries in the error log whenever it detects<br />

a change in the state of a circuit. Note, however, that it is possible two<br />

changed-to-failed-state messages can be entered in the log without an<br />

intervening changed-to-succeeded-state message. Such a series of entries<br />

means that the circuit state continues to be faulty.<br />

C.10.6 Diagnosing CI Cabling Problems<br />

The following paragraphs discuss various incorrect CI cabling configurations and<br />

the entries made in the error log when these configurations exist. Figure C–1<br />

shows a two-computer configuration with all cables correctly connected.<br />

Figure C–2 shows a CI cluster with a pair of crossed cables.<br />

Figure C–1 Correctly Connected Two-Computer CI <strong>Cluster</strong><br />

Local<br />

CI<br />

Port<br />

TA<br />

TB<br />

RA<br />

RB<br />

Figure C–2 Crossed CI Cable Pair<br />

Local<br />

CI<br />

Port<br />

TA<br />

TB<br />

RA<br />

RB<br />

X<br />

Star<br />

Coupler<br />

Star<br />

Coupler<br />

RA<br />

RB<br />

TA<br />

TB<br />

RA<br />

RB<br />

TA<br />

TB<br />

Remote<br />

CI<br />

Port<br />

ZK−1924−GE<br />

Remote<br />

CI<br />

Port<br />

ZK−1925−GE<br />

If a pair of transmitting cables or a pair of receiving cables is crossed, a message<br />

sent on TA is received on RB, and a message sent on TB is received on RA. This<br />

is a hardware error condition from which the port cannot recover. An entry is<br />

made in the error log indicating that a single pair of crossed cables exists. The<br />

entry contains the following lines:<br />

DATA CABLE(S) CHANGE OF STATE<br />

PATH 1. LOOPBACK HAS GONE FROM GOOD TO BAD<br />

If this situation exists, you can correct it by reconnecting the cables properly. The<br />

cables could be misconnected in several places. The coaxial cables that connect<br />

the port boards to the bulkhead cable connectors can be crossed, or the cables can<br />

be misconnected to the bulkhead or the star coupler.<br />