Phase 4 – Wire L.T. Solid State ( Static) Whole Current ... - WBSEDCL

Phase 4 – Wire L.T. Solid State ( Static) Whole Current ... - WBSEDCL

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

12.0 DISPLAY SEQUENCE :The meter should display the required parameters in two different modes as follows:(Display sequence for both auto and Push button must be maintained, nointerchange in sequence or display parameter will be accepted. All the displayshould have proper legend to identify the same.)A. Auto Display Mode:The following parameters should be displayed in auto cycle mode, in the following sequence.Previous Month / Billing RegisterImport onlyExport-Import. LCD test• Meter serial number• Real Date (dd mm yy)Real Time (hh mm ss)• Rising Apparent Demand with elapsedtimePrevious Month / Billing Register• Cumulative Active Forwarded Energy(24 Hours)• TOD Cumulative Active ForwardedEnergy• Cumulative Reactive Energy (Lag 24Hours)• Cumulative Reactive Energy (Lead 24Hours)• Cumulative Apparent Energy (24 Hours)• TOD Cumulative Apparent Energy• Cumulative Apparent Demand (24Hours)• TOD Apparent DemandCumulative Billing CountCumulative Tamper CountPower OFF Hours (Previous Month,i.e. . . since the last M.D. reset).Last Billing reset Date & TimeLCD TestMeter serial numberReal Date ( dd mm yy)Real Time (hh mm ss)Rising Apparent Demand with elapsed time(Import &Export)Previous Month / Billing RegisterCumulative Active Energy Import (24 Hours)Cumulative Active Energy Export (24 Hours)Cumulative Reactive Energy Lag while Active Energy Import(24 Hours)Cumulative Reactive Energy Lag while Active Energy Export(24 Hours)Cumulative Reactive Energy Lead while Active Energy Import(24 Hours)Cumulative Reactive Energy Lead while Active Energy Export(24 Hours)Cumulative Apparent Energy while Active Energy Import (24Hours)Cumulative Apparent Energy while Active Energy Export (24Hours)Cumulative Apparent Max. Demand while Active EnergyImport Lag Only(24 Hours)TOD Wise Active Energies while Active Energy ImportTOD Wise Apparent Energies while Active Energy ImportTOD Wise Apparent Max. Demand while Active EnergyImportEach parameter should be on meter display for <strong>Phase</strong> 10 wise seconds active energy and import the time and export. between two autocycle should be at 120 seconds gap.Cumulative Billing CountCumulative Tamper CountPower OFF Hours (Previous Month)6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!