B. Push Button mode :In addition to the auto display mode parameters, the following parameters should be displayedon pressing the push button (all display of auto mode and the following).Present Month readingImport onlyExport-ImportCumulative Active Forwarded Energy(24hours)TOD Cumulative Active Forwarded Energy(Zone 1,2,3…)Cumulative Reactive Energy (Lag 24Hours)Cumulative Reactive Energy (Lead 24Hours)Cumulative Apparent Energy (24 Hours)TOD Cumulative Apparent Energy (Zone1,2,3…)Cumulative Apparent Demand (24 Hours)Cumulative Apparent Demand sincemanufactureAverage Power Factor ( Previous Month)Instantaneous Power FactorImport –Lag OnlyAvg. Load Factor (Previous Month) i.e.Average Load/Peak Load during theprevious month)MD reset countInstantaneous <strong>Phase</strong> VoltagesInstantaneous <strong>Phase</strong> <strong>Current</strong>sInstantaneous Neutral <strong>Current</strong> i.e. Actual<strong>Current</strong> flowing through the NeutralSigned Inst. Power Factor – <strong>Phase</strong> WiseSigned Inst. Active PowerInst. Apparent PowerInst. FrequencyPresent Tamper Status (PT/CT/Other)First Occurrence with Date & TimeLast Occurrence with Date & TimeLast Restoration with Date & timePrevious 3 months (at least) cumulativeKwh, Kvah and Maximum Demand inKva at 24.00 hrs. of last date of themonth.Cumulative Power failure in hour –minute from the date of manufacturing.High resolution display for KWh, KVARHand KVAH ( minimum 2+4)<strong>Phase</strong> SequenceConnection checkSelf DiagnosisDisplay for Auto and manual mode must be listed by two headersA) Auto Display Mode andB) Push Button Modeand pasted in front of the PP Box.Active Energy ImportActive Energy ExportReactive Energy Lag while Active EnergyImportReactive Energy Lag while Active EnergyExportReactive Energy Lead while Active EnergyImportReactive Energy Lead while Active EnergyExportApparent Energy while Active Energy Import -Lag OnlyApparent Energy while Active Energy Export- Lag OnlyApparent Max. Demand while Active EnergyTOD Wise Active Energies ImportTOD Wise Apparent Energies ImportTOD Wise Apparent Max. Demand ImportCumulative Apparent Maximum Demand ImportInst. <strong>Phase</strong> VoltagesInst. <strong>Phase</strong> <strong>Current</strong>sInstantaneous Neutral <strong>Current</strong>Signed Inst. Power Factor – <strong>Phase</strong> WiseThree <strong>Phase</strong> Power FactorSigned Inst. Active PowerInst. Apparent PowerInst. FrequencyPresent Tamper Status (PT/CT/Other)First Occurrence with Date & TimeLast Occurrence with Date & TimePrevious 3 months (at least) cumulativeKwh, Kvah and Maximum Demand inKva at 24.00 hrs. of last date of themonth.Cumulative Power failure in hoursminutefrom the date of manufacturing.High resolution display for KWh,KVARH and KVAH (minimum 2+4)<strong>Phase</strong> SequenceConnection check. Self DiagnosisEach parameter should be on meter display for 10 seconds and the time between two autocycles should be at least 120 seconds gap.7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!