FR-A701 catalog - Mitsubishi Electric Australia
FR-A701 catalog - Mitsubishi Electric Australia
FR-A701 catalog - Mitsubishi Electric Australia
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Name (type)Surge voltagesuppression filter<strong>FR</strong>-BMF-HK•When driving the 400V class motor by the inverter, this filter suppresses the surge voltage generates at the motor terminal.•This can be appliced to <strong>FR</strong>-A741-5.5K to 37K.•This can be applied to the non insulation-enhanced motor.• Specifications• Connection diagram• Outline dimension• <strong>FR</strong>-BMF-H7.5KSpecifications, Structure, etc.Type <strong>FR</strong>-BMF-HK 7.5 15 22 37Applicable inverter capacity *1 5.5 7.5 11 15 18.5 22 30 37Rated current (A) 17 31 43 71Overload current rating *2150% 60s, 200% 0.5s(inverse-time characteristics)Rated input AC voltage *2Three phase 380 to 480VPermissible AC voltagefluctuation *2323 to 528VMaximum frequency *2120HzPWM carrier frequency 2kHz or less *3EnvironmentProtective structure(JEM 1030)Open type (IP00)Cooling systemSelf-coolingMaximum wiring length100m or lessApproximate mass (kg) 5.5 9.5 11.5 19Ambient temperatureAmbient humidity-10°C to +50°C (non-freezing)90%RH maximum (non-condensing)Three-phaseAC power supplyAtmosphereIndoors (free from corrosive gas, flammable gas, oilmist, dust and dirt)Altitude/vibration Maximum 1,000m above sea level, 5.9m/s 2 or less *4*1 The applied motor capacity indicated is the maximum capacity applicable for use of the <strong>Mitsubishi</strong> 4-pole standard motor.*2 The capacity depends on the specifications of the inverter (400V class) connected.*3 The setting of Pr. 72 PWM frequency selection should be 2kHz or less.*4 When using with the filter pack installed on the rear panel, do not install this combination on moving objects or places that have vibrations(exceeding 1.96m/s 2 ).4-M54-M4Earth terminal (M5)230208195150Terminal layoutX Y Z TH0TH1138149.52-φ6 hole2453253403257545Ratingplate13.5• <strong>FR</strong>-BMF-H15K, H22K4-M86-M5Earth terminal(M6)260230195180Terminal layoutX Y Z TH0TH1MCCBONMC245T*MCOFFMCInverterRSTUVW* Install a step-down transformer.2852051652-φ10 hole38048050045710050 31Ratingplate<strong>FR</strong>-BMFXYZTH0TH1Within100mMotorIM37060Red White Blue(U) (V) (W)Isolation cap colorMain terminal block (M4)2.367.57.5Crimping terminal 5.5-4Control terminal block (M3)6420Red White Blue(U) (V) (W)Isolation cap colorMain terminal block (M5)2.31080103310Crimping terminal 8-6Control terminal block (M3)2.32.3•<strong>FR</strong>-BMF-H37K2452-φ10 hole550525Earth terminal(M8)RatingplateTerminal layoutX Y ZTH0TH12.345012.5Red White BlueCrimping terminal 22-6(U) (V) (W)Isolation cap colorMain terminal block (M6)108013029Control terminal block (M3)(Unit: mm)