4 Specifications *Accuracy:Analysis Ranges:Application:Approvals:Area Classification:Calibration:Compensation:Connections:< 1% of FS range under constant conditions0-10 <strong>ppm</strong>, 0-100, 0-1000 <strong>ppm</strong>, 0-1% plus 0-25% FS rangefor air calibration; auto-ranging or lock on single rangeAnalyze oxygen concentrations from 100 ppb to 1% in inert,hydrocarbon, helium, hydrogen, mixed and acid (CO 2 ) gasstreamsCE, Intrinsic Safety (pending, void with optional generalpurpose sampling pump)Meets standards for Class 1, Division 1, Group C, Dhazardous areas (void with optional general purpose pump)Certified gas of O 2 balance N 2 approximating 80% of analysisrange or one range above analysis rangeTemperature and barometric pressure1/8" compression tube fittingsControls:Display:Enclosure:Flow Sensitivity:LED Indicators:Linearity:Pressure:Power:Recovery Time:Water resistant keypad; menu driven range selection,calibration and system functionsGraphical LCD 2.75 x 1.375”; resolution .01 <strong>ppm</strong>; displaysreal time ambient temperature and pressurePainted aluminum NEMA 4X, 8.6 x 9 x 3", 12 lbs.None between 0.5-5 SCFH, 2 SCFH recommendedLOW BATT (72 hr. warning); CHARGE mode> .995 over all rangesInlet - regulate to 5-30 psig; vent - atmosphericRechargeable battery, 60 day duty cycle (pump 1 day)60 seconds in air to < 10 <strong>ppm</strong> in < 1 hr on N 2 purgeResponse Time: 90% of final FS reading in 10 secondsSample System: Flow control and sample/bypass valves; flow indicatorSensitivity:< 0.5% of FS rangeSensor Model: <strong>GPR</strong>-12-333Sensor Life: 24 months at 25ºC, 1 atm and average O 2 < 1,000 <strong>ppm</strong>Signal Output: 0-1VTemp. Range:5º to 45ºC (<strong>GPR</strong> sensor), -20º to 45ºC (XLT sensor)<strong>GPR</strong>-<strong>1200</strong><strong>Portable</strong> <strong>ppm</strong> O 2 <strong>Analyzer</strong><strong>Advanced</strong> Sensor TechnologyAccuracy < 1% FS RangeSensitivity < 0.5% FS RangeFast Recovery to < 10 <strong>ppm</strong>24 Month Expected LifeNo MaintenanceCompatible in 0-100% CO 2Intrinsically Safe DesignAuto or Manual Ranging4 Standard Analysis Ranges0-25% Range for Air CalibrationSS Bypass Sample SystemISO 9001:2008 Certified QA SystemWarranty:12 months analyzer; 12 months sensorWetted Parts: Stainless steelOptional EquipmentXLT-12-333 sensor with > 0.5% CO 2 presentIntegral sampling pump - general purpose or intrinsically safe designsCarrying case with custom foam insertSample conditioning accessories - contact factory* Specifications subject to change without noticeIntegral bypass sample system increases productivity.8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!